MG301
4G Metering Gateway
MG301 is a cellular gateway designed for automated meter reading. It connects field meters to head-end systems over 4G networks, supporting multiple metering protocols, flexible interfaces, and reliable remote communication.
MG301
4G Metering Gateway
MG301 is a cellular gateway designed for automated meter reading. It connects field meters to head-end systems over 4G networks, supporting multiple metering protocols, flexible interfaces, and reliable remote communication.
写真
Built for Reliable Remote Meter Reading
Reliable 4G Connectivity
LTE Cat.1/Cat.4 options, automatic link recovery, and built-in watchdog mechanisms help maintain reliable communication across distributed metering sites.
Multiple Metering Protocols
Supports IEC 62056-21 Mode C, DLMS/COSEM, and Modbus RTU for communication with a wide range of compatible meters.
Flexible Interfaces for Field Integration
Dual isolated RS485 ports and built-in digital I/O support diverse field connections, with Ethernet and relay outputs available as options.
Head-End System Integration
Supports MQTT/MQTTS, MASS, and TeleMetriX Head-End protocols for data communication with compatible meter data collection systems.
Event Detection & Remote Maintenance
Power failure and enclosure-opening detection help identify field issues, while remote firmware upgrades simplify ongoing maintenance.
工業グレード設計
Wide-range 55–270 VAC input, -30°C to 70°C operation, and Li-ion battery or supercapacitor options support deployment in demanding electrical environments.
-
主要技術仕様
セルラー 4G cellular module, CAT1/CAT4ハードウェアプラットフォーム MIPS24KEc (575/580 MHz); 128MB RAM; 64MB FlashMetering Protocols IEC62056-21 Mode-C; DLMS/COSEM; Modbus RTUPlatform Access MQTT/MQTTS/MASS/TeleMetriX Head-Endインターフェース 2 × isolated RS485; 1 × USB2.0 Type-C; 4 × DI; 2 × DO; 2 × latching relay outputs (optional); 1 × 100Mbps Ethernet (optional)力 55–270 VAC, nominal 230 V; 20 VA (max.)寸法 130 × 125 × 68 mm (specification table)動作環境 -30 to 70 °C; 0–93% ambient humidity保護 IP40
-
Product Interfaces
イーサネット 1 × 100Mbps Ethernet port, RJ45 connector (optional)セルラー 4G cellular module, CAT1/CAT4USB 1 × USB2.0, Type-Cシリアルポート 2 × RS485, isolated, terminal-block connector; RS485: Data+, Data-, GNDSIMカード Mini SIM-2FF card, supports 1.8/3V SIM/UIM card; eSIMアンテナコネクタ 1 × Cellular Antennaボタン 1 × System reset buttonOpen Lid Detection 1 × Open Cover Inspection keyRelay Outputs 2 × relay outputs: 240VAC/5A, latching relay output (optional)Digital Inputs 4 × digital inputs; isolation voltage: 3500 V; dry contact: Logic 1, Open; Logic 0, Close to ground; wet contact: VIH(max.) = 30 VDC, VIH(min.) = 5 VDC, VIL(max.) = 2 VDCDigital Outputs 2 × digital outputs; isolation voltage: 3500 V; supply voltage: 20 V max.; sink current: 0.5 A max.
-
ハードウェアプラットフォーム
CPU MIPS24KEc (575/580 MHz)ラム 128MBフラッシュ 64MB
-
インターフェース
イーサネットポート 1 × 100Mbps Ethernet port, RJ45 connector (optional)セルラー 4G cellular module, CAT1/CAT4USB 1 × USB2.0, Type-Cシリアルポート 2 × RS485, isolated, terminal-block connector; RS485: Data+, Data-, GNDSIMカード Mini SIM-2FF, supports 1.8/3V SIM/UIM card; eSIMアンテナコネクタ 1 × Cellular Antennaボタン 1 × System reset buttonOpen Lid Detection Device 1 × Open Cover Inspection keyRelay Outputs 2 × relay outputs: 240VAC/5A, latching relay output (optional)Digital Inputs 4 × digital inputs; isolation voltage: 3500 V; dry contact: Logic 1, Open; Logic 0, Close to ground; wet contact: VIH(max.) = 30 VDC, VIH(min.) = 5 VDC, VIL(max.) = 2 VDCDigital Outputs 2 × digital outputs; isolation voltage: 3500 V; supply voltage: 20 V max.; sink current: 0.5 A max.
-
Other Hardware
RTC Real time clock operated from on-board coin-cell batteryPunctuality Accuracy 0.5 S/dayバッテリー Li-ion battery (500mAh) or supercapacitor (Li-ion battery default)
-
力
電源 AC input: unregulated 55V to 270 VAC, nominal 230V, instantaneous voltage protection of 6KV; reverse voltage protection消費電力 20VA (max.)
-
機械的特性
取り付け DIN rail / mounting ear (default)筐体材質 プラスチックDimension 130 × 125 × 61 mm保護 IP40
-
Ambient Temperature and Humidity
動作温度 -30 to 70 °C周囲の湿度 0–93%Declared Pollution Degree 3Overvoltage Category CAT III
-
導かれた
システム 1 × Power, 3 × CSQ, 1 × IP, 1 × 4G, 1 × GPRS, 2 × RS485, 2 × Relay
-
Safety & EMC
Safety & EMC IEC 62368-1; EN 55032 Class B; EN 55035 Level 3
-
Other Standards
その他 EN 60068-2-30; EN 60068-2-31; EN 60068-2-1; EN 60068-2-2; EN 62262; IEC 60529; IEC 60695-11-10 standard V-0 class
-
オペレーティング·システム
OS Linux
-
インターネット
Access authentication APN、VPDNInternet access チャップ、パップNetwork format LTE CAT 1
-
Network Protocol
知的財産権の適用 ICMP, DNS, TCP/UDP, TCP Server, DHCP, NTPIPルーティング 静的ルーティング
-
信頼性
Cover Opening Alarm Detection lid is opened停電警報 Detecting an external power failureリンク検出 ハートビートパケットを送信して検出し、切断された場合は自動的に再ダイヤルします。組み込み型監視システム デバイスは自己診断を実行し、故障から自動的に復旧します。Temperature Detection The CPU temperature can be detected and recorded in logs
-
Communication Protocol
Acquisition Protocol IEC62056-21 Mode-C; DLMS/COSEM; Modbus RTUAccess Platform MQTT/MQTTS/MASS/TeleMetriX Head-End
-
ネットワーク管理
構成 Web via USB/ETHアップグレード Local via USB/ETH; remote via FTP/InHand DM platformログ Support local system log and important log power-off autosave
Datasheets
Flyers
標準パッケージ*
- MG301 Metering Gateway *1
- Cellular Antenna *1
※標準パッケージの内容は、標準クレジットカードコードによって異なります。
オプションアクセサリー
- Wall Mount Kit *1
お問い合わせ パッケージオプションの詳細については、直接お問い合わせください。
仕様
-
主要技術仕様
セルラー 4G cellular module, CAT1/CAT4ハードウェアプラットフォーム MIPS24KEc (575/580 MHz); 128MB RAM; 64MB FlashMetering Protocols IEC62056-21 Mode-C; DLMS/COSEM; Modbus RTUPlatform Access MQTT/MQTTS/MASS/TeleMetriX Head-Endインターフェース 2 × isolated RS485; 1 × USB2.0 Type-C; 4 × DI; 2 × DO; 2 × latching relay outputs (optional); 1 × 100Mbps Ethernet (optional)力 55–270 VAC, nominal 230 V; 20 VA (max.)寸法 130 × 125 × 68 mm (specification table)動作環境 -30 to 70 °C; 0–93% ambient humidity保護 IP40
-
Product Interfaces
イーサネット 1 × 100Mbps Ethernet port, RJ45 connector (optional)セルラー 4G cellular module, CAT1/CAT4USB 1 × USB2.0, Type-Cシリアルポート 2 × RS485, isolated, terminal-block connector; RS485: Data+, Data-, GNDSIMカード Mini SIM-2FF card, supports 1.8/3V SIM/UIM card; eSIMアンテナコネクタ 1 × Cellular Antennaボタン 1 × System reset buttonOpen Lid Detection 1 × Open Cover Inspection keyRelay Outputs 2 × relay outputs: 240VAC/5A, latching relay output (optional)Digital Inputs 4 × digital inputs; isolation voltage: 3500 V; dry contact: Logic 1, Open; Logic 0, Close to ground; wet contact: VIH(max.) = 30 VDC, VIH(min.) = 5 VDC, VIL(max.) = 2 VDCDigital Outputs 2 × digital outputs; isolation voltage: 3500 V; supply voltage: 20 V max.; sink current: 0.5 A max.
-
ハードウェアプラットフォーム
CPU MIPS24KEc (575/580 MHz)ラム 128MBフラッシュ 64MB
-
インターフェース
イーサネットポート 1 × 100Mbps Ethernet port, RJ45 connector (optional)セルラー 4G cellular module, CAT1/CAT4USB 1 × USB2.0, Type-Cシリアルポート 2 × RS485, isolated, terminal-block connector; RS485: Data+, Data-, GNDSIMカード Mini SIM-2FF, supports 1.8/3V SIM/UIM card; eSIMアンテナコネクタ 1 × Cellular Antennaボタン 1 × System reset buttonOpen Lid Detection Device 1 × Open Cover Inspection keyRelay Outputs 2 × relay outputs: 240VAC/5A, latching relay output (optional)Digital Inputs 4 × digital inputs; isolation voltage: 3500 V; dry contact: Logic 1, Open; Logic 0, Close to ground; wet contact: VIH(max.) = 30 VDC, VIH(min.) = 5 VDC, VIL(max.) = 2 VDCDigital Outputs 2 × digital outputs; isolation voltage: 3500 V; supply voltage: 20 V max.; sink current: 0.5 A max.
-
Other Hardware
RTC Real time clock operated from on-board coin-cell batteryPunctuality Accuracy 0.5 S/dayバッテリー Li-ion battery (500mAh) or supercapacitor (Li-ion battery default)
-
力
電源 AC input: unregulated 55V to 270 VAC, nominal 230V, instantaneous voltage protection of 6KV; reverse voltage protection消費電力 20VA (max.)
-
機械的特性
取り付け DIN rail / mounting ear (default)筐体材質 プラスチックDimension 130 × 125 × 61 mm保護 IP40
-
Ambient Temperature and Humidity
動作温度 -30 to 70 °C周囲の湿度 0–93%Declared Pollution Degree 3Overvoltage Category CAT III
-
導かれた
システム 1 × Power, 3 × CSQ, 1 × IP, 1 × 4G, 1 × GPRS, 2 × RS485, 2 × Relay
-
Safety & EMC
Safety & EMC IEC 62368-1; EN 55032 Class B; EN 55035 Level 3
-
Other Standards
その他 EN 60068-2-30; EN 60068-2-31; EN 60068-2-1; EN 60068-2-2; EN 62262; IEC 60529; IEC 60695-11-10 standard V-0 class
-
オペレーティング·システム
OS Linux
-
インターネット
Access authentication APN、VPDNInternet access チャップ、パップNetwork format LTE CAT 1
-
Network Protocol
知的財産権の適用 ICMP, DNS, TCP/UDP, TCP Server, DHCP, NTPIPルーティング 静的ルーティング
-
信頼性
Cover Opening Alarm Detection lid is opened停電警報 Detecting an external power failureリンク検出 ハートビートパケットを送信して検出し、切断された場合は自動的に再ダイヤルします。組み込み型監視システム デバイスは自己診断を実行し、故障から自動的に復旧します。Temperature Detection The CPU temperature can be detected and recorded in logs
-
Communication Protocol
Acquisition Protocol IEC62056-21 Mode-C; DLMS/COSEM; Modbus RTUAccess Platform MQTT/MQTTS/MASS/TeleMetriX Head-End
-
ネットワーク管理
構成 Web via USB/ETHアップグレード Local via USB/ETH; remote via FTP/InHand DM platformログ Support local system log and important log power-off autosave
ダウンロード
Datasheets
Flyers
注文
標準パッケージ*
- MG301 Metering Gateway *1
- Cellular Antenna *1
※標準パッケージの内容は、標準クレジットカードコードによって異なります。
オプションアクセサリー
- Wall Mount Kit *1
お問い合わせ パッケージオプションの詳細については、直接お問い合わせください。
関連事例
Multi-Meter Remote Reading and Centralized Management for Smart Grids
MG301 connects multiple smart meters and enables remote meter reading over 4G,…
詳細はこちら →よくある質問
What is MG301 designed for?
MG301 is designed for automated meter reading applications. It enables head-end systems to communicate with field meters over cellular networks, retrieve meter data, and monitor meter operating parameters.
What metering protocols does MG301 support?
MG301 supports IEC 62056-21 Mode C, DLMS/COSEM, and Modbus RTU. Compatibility with individual meters depends on their communication interfaces and protocol implementations.
What interfaces are available on MG301?
MG301 provides two isolated RS485 ports, four digital inputs, two digital outputs, and a USB Type-C port. Ethernet and latching relay outputs are available as options.
How does MG301 maintain communication reliability?
MG301 uses link monitoring, automatic reconnection, and hardware and software watchdog mechanisms to detect communication issues and recover from interruptions.