Frag die KI alles

MG301
4G Metering Gateway

MG301 is a cellular gateway designed for automated meter reading. It connects field meters to head-end systems over 4G networks, supporting multiple metering protocols, flexible interfaces, and reliable remote communication.

MG301
4G Metering Gateway

MG301 is a cellular gateway designed for automated meter reading. It connects field meters to head-end systems over 4G networks, supporting multiple metering protocols, flexible interfaces, and reliable remote communication.

FOTO

Built for Reliable Remote Meter Reading

Reliable 4G Connectivity

LTE Cat.1/Cat.4 options, automatic link recovery, and built-in watchdog mechanisms help maintain reliable communication across distributed metering sites.

Breite Protokollunterstützung

Multiple Metering Protocols

Supports IEC 62056-21 Mode C, DLMS/COSEM, and Modbus RTU for communication with a wide range of compatible meters.

Protocol transparency

 Flexible Interfaces for Field Integration

Dual isolated RS485 ports and built-in digital I/O support diverse field connections, with Ethernet and relay outputs available as options.

Edge-Datenüberwachung

Head-End System Integration

Supports MQTT/MQTTS, MASS, and TeleMetriX Head-End protocols for data communication with compatible meter data collection systems.

Event Detection & Remote Maintenance

Power failure and enclosure-opening detection help identify field issues, while remote firmware upgrades simplify ongoing maintenance.

Industriequalität

Wide-range 55–270 VAC input, -30°C to 70°C operation, and Li-ion battery or supercapacitor options support deployment in demanding electrical environments.

  • Wichtigste technische Spezifikationen
    Mobilfunk 4G cellular module, CAT1/CAT4
    Hardwareplattform MIPS24KEc (575/580 MHz); 128MB RAM; 64MB Flash
    Metering Protocols IEC62056-21 Mode-C; DLMS/COSEM; Modbus RTU
    Platform Access MQTT/MQTTS/MASS/TeleMetriX Head-End
    Schnittstellen 2 × isolated RS485; 1 × USB2.0 Type-C; 4 × DI; 2 × DO; 2 × latching relay outputs (optional); 1 × 100Mbps Ethernet (optional)
    Leistung 55–270 VAC, nominal 230 V; 20 VA (max.)
    Abmessungen 130 × 125 × 68 mm (specification table)
    Betriebsumgebung -30 to 70 °C; 0–93% ambient humidity
    Schutz IP40
  • Product Interfaces
    Ethernet 1 × 100Mbps Ethernet port, RJ45 connector (optional)
    Mobilfunk 4G cellular module, CAT1/CAT4
    USB 1 × USB2.0, Type-C
    Serielle Schnittstelle 2 × RS485, isolated, terminal-block connector; RS485: Data+, Data-, GND
    SIM-Karte Mini SIM-2FF card, supports 1.8/3V SIM/UIM card; eSIM
    Antennenanschluss 1 × Cellular Antenna
    Taste 1 × System reset button
    Open Lid Detection 1 × Open Cover Inspection key
    Relay Outputs 2 × relay outputs: 240VAC/5A, latching relay output (optional)
    Digital Inputs 4 × digital inputs; isolation voltage: 3500 V; dry contact: Logic 1, Open; Logic 0, Close to ground; wet contact: VIH(max.) = 30 VDC, VIH(min.) = 5 VDC, VIL(max.) = 2 VDC
    Digital Outputs 2 × digital outputs; isolation voltage: 3500 V; supply voltage: 20 V max.; sink current: 0.5 A max.
  • Hardwareplattform
    CPU MIPS24KEc (575/580 MHz)
    RAM 128 MB
    BLITZ 64MB
  • Schnittstellen
    Ethernet-Anschluss 1 × 100Mbps Ethernet port, RJ45 connector (optional)
    Mobilfunk 4G cellular module, CAT1/CAT4
    USB 1 × USB2.0, Type-C
    Serielle Schnittstelle 2 × RS485, isolated, terminal-block connector; RS485: Data+, Data-, GND
    SIM-Karte Mini SIM-2FF, supports 1.8/3V SIM/UIM card; eSIM
    Antennenanschluss 1 × Cellular Antenna
    Taste 1 × System reset button
    Open Lid Detection Device 1 × Open Cover Inspection key
    Relay Outputs 2 × relay outputs: 240VAC/5A, latching relay output (optional)
    Digital Inputs 4 × digital inputs; isolation voltage: 3500 V; dry contact: Logic 1, Open; Logic 0, Close to ground; wet contact: VIH(max.) = 30 VDC, VIH(min.) = 5 VDC, VIL(max.) = 2 VDC
    Digital Outputs 2 × digital outputs; isolation voltage: 3500 V; supply voltage: 20 V max.; sink current: 0.5 A max.
  • Other Hardware
    RTC Real time clock operated from on-board coin-cell battery
    Punctuality Accuracy 0.5 S/day
    Batterie Li-ion battery (500mAh) or supercapacitor (Li-ion battery default)
  • Leistung
    Stromversorgung AC input: unregulated 55V to 270 VAC, nominal 230V, instantaneous voltage protection of 6KV; reverse voltage protection
    Stromverbrauch 20VA (max.)
  • Mechanische Eigenschaften
    Montage DIN rail / mounting ear (default)
    Gehäusematerial Plastik
    Dimension 130 × 125 × 61 mm
    Schutz IP40
  • Ambient Temperature and Humidity
    Betriebstemperatur -30 to 70 °C
    Umgebungsfeuchtigkeit 0–93%
    Declared Pollution Degree 3
    Overvoltage Category CAT III
  • LED
    System 1 × Power, 3 × CSQ, 1 × IP, 1 × 4G, 1 × GPRS, 2 × RS485, 2 × Relay
  • Safety & EMC
    Safety & EMC IEC 62368-1; EN 55032 Class B; EN 55035 Level 3
  • Other Standards
    Andere EN 60068-2-30; EN 60068-2-31; EN 60068-2-1; EN 60068-2-2; EN 62262; IEC 60529; IEC 60695-11-10 standard V-0 class
  • Betriebssystem
    Betriebssystem Linux
  • Internet
    Access authentication APN, VPDN
    Internet access CHAP, PAP
    Network format LTE CAT 1
  • Network Protocol
    IP-Anwendung ICMP, DNS, TCP/UDP, TCP Server, DHCP, NTP
    IP-Routing Statisches Routing
  • Zuverlässigkeit
    Cover Opening Alarm Detection lid is opened
    Stromausfallalarm Detecting an external power failure
    Linkerkennung Sendet Heartbeat-Pakete zur Erkennung und wählt sich bei Verbindungsabbruch automatisch wieder.
    Eingebetteter Wachhund Das Gerät führt eine Selbstdiagnose durch und behebt Fehlfunktionen automatisch.
    Temperature Detection The CPU temperature can be detected and recorded in logs
  • Communication Protocol
    Acquisition Protocol IEC62056-21 Mode-C; DLMS/COSEM; Modbus RTU
    Access Platform MQTT/MQTTS/MASS/TeleMetriX Head-End
  • Netzwerkmanagement
    Konfiguration Web via USB/ETH
    Upgrade Local via USB/ETH; remote via FTP/InHand DM platform
    Protokoll Support local system log and important log power-off autosave

Datenblätter

MG301_Datasheet_V1.3
10.21.2026 1.3 MB

Standardpaket*

  • MG301 Metering Gateway *1
  • Cellular Antenna *1

*Der Standardpackungsinhalt variiert je nach Standard-CRDER-Code.

Optionales Zubehör

  • Wall Mount Kit *1

Kontaktieren Sie uns Um mehr über unsere Verpackungsoptionen zu erfahren, wenden Sie sich bitte direkt an uns.

Spezifikationen
  • Wichtigste technische Spezifikationen
    Mobilfunk 4G cellular module, CAT1/CAT4
    Hardwareplattform MIPS24KEc (575/580 MHz); 128MB RAM; 64MB Flash
    Metering Protocols IEC62056-21 Mode-C; DLMS/COSEM; Modbus RTU
    Platform Access MQTT/MQTTS/MASS/TeleMetriX Head-End
    Schnittstellen 2 × isolated RS485; 1 × USB2.0 Type-C; 4 × DI; 2 × DO; 2 × latching relay outputs (optional); 1 × 100Mbps Ethernet (optional)
    Leistung 55–270 VAC, nominal 230 V; 20 VA (max.)
    Abmessungen 130 × 125 × 68 mm (specification table)
    Betriebsumgebung -30 to 70 °C; 0–93% ambient humidity
    Schutz IP40
  • Product Interfaces
    Ethernet 1 × 100Mbps Ethernet port, RJ45 connector (optional)
    Mobilfunk 4G cellular module, CAT1/CAT4
    USB 1 × USB2.0, Type-C
    Serielle Schnittstelle 2 × RS485, isolated, terminal-block connector; RS485: Data+, Data-, GND
    SIM-Karte Mini SIM-2FF card, supports 1.8/3V SIM/UIM card; eSIM
    Antennenanschluss 1 × Cellular Antenna
    Taste 1 × System reset button
    Open Lid Detection 1 × Open Cover Inspection key
    Relay Outputs 2 × relay outputs: 240VAC/5A, latching relay output (optional)
    Digital Inputs 4 × digital inputs; isolation voltage: 3500 V; dry contact: Logic 1, Open; Logic 0, Close to ground; wet contact: VIH(max.) = 30 VDC, VIH(min.) = 5 VDC, VIL(max.) = 2 VDC
    Digital Outputs 2 × digital outputs; isolation voltage: 3500 V; supply voltage: 20 V max.; sink current: 0.5 A max.
  • Hardwareplattform
    CPU MIPS24KEc (575/580 MHz)
    RAM 128 MB
    BLITZ 64MB
  • Schnittstellen
    Ethernet-Anschluss 1 × 100Mbps Ethernet port, RJ45 connector (optional)
    Mobilfunk 4G cellular module, CAT1/CAT4
    USB 1 × USB2.0, Type-C
    Serielle Schnittstelle 2 × RS485, isolated, terminal-block connector; RS485: Data+, Data-, GND
    SIM-Karte Mini SIM-2FF, supports 1.8/3V SIM/UIM card; eSIM
    Antennenanschluss 1 × Cellular Antenna
    Taste 1 × System reset button
    Open Lid Detection Device 1 × Open Cover Inspection key
    Relay Outputs 2 × relay outputs: 240VAC/5A, latching relay output (optional)
    Digital Inputs 4 × digital inputs; isolation voltage: 3500 V; dry contact: Logic 1, Open; Logic 0, Close to ground; wet contact: VIH(max.) = 30 VDC, VIH(min.) = 5 VDC, VIL(max.) = 2 VDC
    Digital Outputs 2 × digital outputs; isolation voltage: 3500 V; supply voltage: 20 V max.; sink current: 0.5 A max.
  • Other Hardware
    RTC Real time clock operated from on-board coin-cell battery
    Punctuality Accuracy 0.5 S/day
    Batterie Li-ion battery (500mAh) or supercapacitor (Li-ion battery default)
  • Leistung
    Stromversorgung AC input: unregulated 55V to 270 VAC, nominal 230V, instantaneous voltage protection of 6KV; reverse voltage protection
    Stromverbrauch 20VA (max.)
  • Mechanische Eigenschaften
    Montage DIN rail / mounting ear (default)
    Gehäusematerial Plastik
    Dimension 130 × 125 × 61 mm
    Schutz IP40
  • Ambient Temperature and Humidity
    Betriebstemperatur -30 to 70 °C
    Umgebungsfeuchtigkeit 0–93%
    Declared Pollution Degree 3
    Overvoltage Category CAT III
  • LED
    System 1 × Power, 3 × CSQ, 1 × IP, 1 × 4G, 1 × GPRS, 2 × RS485, 2 × Relay
  • Safety & EMC
    Safety & EMC IEC 62368-1; EN 55032 Class B; EN 55035 Level 3
  • Other Standards
    Andere EN 60068-2-30; EN 60068-2-31; EN 60068-2-1; EN 60068-2-2; EN 62262; IEC 60529; IEC 60695-11-10 standard V-0 class
  • Betriebssystem
    Betriebssystem Linux
  • Internet
    Access authentication APN, VPDN
    Internet access CHAP, PAP
    Network format LTE CAT 1
  • Network Protocol
    IP-Anwendung ICMP, DNS, TCP/UDP, TCP Server, DHCP, NTP
    IP-Routing Statisches Routing
  • Zuverlässigkeit
    Cover Opening Alarm Detection lid is opened
    Stromausfallalarm Detecting an external power failure
    Linkerkennung Sendet Heartbeat-Pakete zur Erkennung und wählt sich bei Verbindungsabbruch automatisch wieder.
    Eingebetteter Wachhund Das Gerät führt eine Selbstdiagnose durch und behebt Fehlfunktionen automatisch.
    Temperature Detection The CPU temperature can be detected and recorded in logs
  • Communication Protocol
    Acquisition Protocol IEC62056-21 Mode-C; DLMS/COSEM; Modbus RTU
    Access Platform MQTT/MQTTS/MASS/TeleMetriX Head-End
  • Netzwerkmanagement
    Konfiguration Web via USB/ETH
    Upgrade Local via USB/ETH; remote via FTP/InHand DM platform
    Protokoll Support local system log and important log power-off autosave

Datenblätter

MG301_Datasheet_V1.3
10.21.2026 1.3 MB

Standardpaket*

  • MG301 Metering Gateway *1
  • Cellular Antenna *1

*Der Standardpackungsinhalt variiert je nach Standard-CRDER-Code.

Optionales Zubehör

  • Wall Mount Kit *1

Kontaktieren Sie uns Um mehr über unsere Verpackungsoptionen zu erfahren, wenden Sie sich bitte direkt an uns.

Ähnliche Fälle

Vorschau
Multi-Meter Remote Reading and Centralized Management for Smart Grids

Multi-Meter Remote Reading and Centralized Management for Smart Grids

MG301 connects multiple smart meters and enables remote meter reading over 4G,…

Mehr erfahren →
Alle Fälle anzeigen

Häufig gestellte Fragen

What is MG301 designed for?

MG301 is designed for automated meter reading applications. It enables head-end systems to communicate with field meters over cellular networks, retrieve meter data, and monitor meter operating parameters.

MG301 supports IEC 62056-21 Mode C, DLMS/COSEM, and Modbus RTU. Compatibility with individual meters depends on their communication interfaces and protocol implementations.

MG301 provides two isolated RS485 ports, four digital inputs, two digital outputs, and a USB Type-C port. Ethernet and latching relay outputs are available as options.

MG301 uses link monitoring, automatic reconnection, and hardware and software watchdog mechanisms to detect communication issues and recover from interruptions.

Das könnte Ihnen auch gefallen