Pregúntale cualquier cosa a la IA

MG301
4G Metering Gateway

MG301 is a cellular gateway designed for automated meter reading. It connects field meters to head-end systems over 4G networks, supporting multiple metering protocols, flexible interfaces, and reliable remote communication.

MG301
4G Metering Gateway

MG301 is a cellular gateway designed for automated meter reading. It connects field meters to head-end systems over 4G networks, supporting multiple metering protocols, flexible interfaces, and reliable remote communication.

FOTO

Built for Reliable Remote Meter Reading

Reliable 4G Connectivity

LTE Cat.1/Cat.4 options, automatic link recovery, and built-in watchdog mechanisms help maintain reliable communication across distributed metering sites.

Amplio soporte de protocolo

Multiple Metering Protocols

Supports IEC 62056-21 Mode C, DLMS/COSEM, and Modbus RTU for communication with a wide range of compatible meters.

Protocol transparency

 Flexible Interfaces for Field Integration

Dual isolated RS485 ports and built-in digital I/O support diverse field connections, with Ethernet and relay outputs available as options.

Monitorización de datos en el borde

Head-End System Integration

Supports MQTT/MQTTS, MASS, and TeleMetriX Head-End protocols for data communication with compatible meter data collection systems.

Event Detection & Remote Maintenance

Power failure and enclosure-opening detection help identify field issues, while remote firmware upgrades simplify ongoing maintenance.

Diseño de grado industrial

Wide-range 55–270 VAC input, -30°C to 70°C operation, and Li-ion battery or supercapacitor options support deployment in demanding electrical environments.

  • Especificaciones técnicas clave
    Celular 4G cellular module, CAT1/CAT4
    Plataforma de hardware MIPS24KEc (575/580 MHz); 128MB RAM; 64MB Flash
    Metering Protocols IEC62056-21 Mode-C; DLMS/COSEM; Modbus RTU
    Platform Access MQTT/MQTTS/MASS/TeleMetriX Head-End
    Interfaces 2 × isolated RS485; 1 × USB2.0 Type-C; 4 × DI; 2 × DO; 2 × latching relay outputs (optional); 1 × 100Mbps Ethernet (optional)
    Fuerza 55–270 VAC, nominal 230 V; 20 VA (max.)
    Dimensiones 130 × 125 × 68 mm (specification table)
    Entorno operativo -30 to 70 °C; 0–93% ambient humidity
    Protección IP40
  • Product Interfaces
    Ethernet 1 × 100Mbps Ethernet port, RJ45 connector (optional)
    Celular 4G cellular module, CAT1/CAT4
    USB 1 × USB2.0, Type-C
    Puerto serie 2 × RS485, isolated, terminal-block connector; RS485: Data+, Data-, GND
    Tarjeta SIM Mini SIM-2FF card, supports 1.8/3V SIM/UIM card; eSIM
    Conector de antena 1 × Cellular Antenna
    Botón 1 × System reset button
    Open Lid Detection 1 × Open Cover Inspection key
    Relay Outputs 2 × relay outputs: 240VAC/5A, latching relay output (optional)
    Digital Inputs 4 × digital inputs; isolation voltage: 3500 V; dry contact: Logic 1, Open; Logic 0, Close to ground; wet contact: VIH(max.) = 30 VDC, VIH(min.) = 5 VDC, VIL(max.) = 2 VDC
    Digital Outputs 2 × digital outputs; isolation voltage: 3500 V; supply voltage: 20 V max.; sink current: 0.5 A max.
  • Plataforma de hardware
    UPC MIPS24KEc (575/580 MHz)
    RAM 128 MB
    DESTELLO 64MB
  • Interfaces
    Puerto Ethernet 1 × 100Mbps Ethernet port, RJ45 connector (optional)
    Celular 4G cellular module, CAT1/CAT4
    USB 1 × USB2.0, Type-C
    Puerto serie 2 × RS485, isolated, terminal-block connector; RS485: Data+, Data-, GND
    Tarjeta SIM Mini SIM-2FF, supports 1.8/3V SIM/UIM card; eSIM
    Conector de antena 1 × Cellular Antenna
    Botón 1 × System reset button
    Open Lid Detection Device 1 × Open Cover Inspection key
    Relay Outputs 2 × relay outputs: 240VAC/5A, latching relay output (optional)
    Digital Inputs 4 × digital inputs; isolation voltage: 3500 V; dry contact: Logic 1, Open; Logic 0, Close to ground; wet contact: VIH(max.) = 30 VDC, VIH(min.) = 5 VDC, VIL(max.) = 2 VDC
    Digital Outputs 2 × digital outputs; isolation voltage: 3500 V; supply voltage: 20 V max.; sink current: 0.5 A max.
  • Other Hardware
    RTC Real time clock operated from on-board coin-cell battery
    Punctuality Accuracy 0.5 S/day
    Batería Li-ion battery (500mAh) or supercapacitor (Li-ion battery default)
  • Fuerza
    Fuente de alimentación AC input: unregulated 55V to 270 VAC, nominal 230V, instantaneous voltage protection of 6KV; reverse voltage protection
    Consumo de energía 20VA (max.)
  • Características mecánicas
    Montaje DIN rail / mounting ear (default)
    Material de la carcasa Plástico
    Dimension 130 × 125 × 61 mm
    Protección IP40
  • Ambient Temperature and Humidity
    Temperatura de funcionamiento -30 to 70 °C
    Humedad ambiental 0–93%
    Declared Pollution Degree 3
    Overvoltage Category CAT III
  • CONDUJO
    Sistema 1 × Power, 3 × CSQ, 1 × IP, 1 × 4G, 1 × GPRS, 2 × RS485, 2 × Relay
  • Safety & EMC
    Safety & EMC IEC 62368-1; EN 55032 Class B; EN 55035 Level 3
  • Other Standards
    Otros EN 60068-2-30; EN 60068-2-31; EN 60068-2-1; EN 60068-2-2; EN 62262; IEC 60529; IEC 60695-11-10 standard V-0 class
  • Sistema operativo
    Sistema operativo Linux
  • Internet
    Access authentication APN, VPDN
    Internet access CHAP, PAP
    Network format LTE CAT 1
  • Network Protocol
    Aplicación de propiedad intelectual ICMP, DNS, TCP/UDP, TCP Server, DHCP, NTP
    Enrutamiento IP Enrutamiento estático
  • Fiabilidad
    Cover Opening Alarm Detection lid is opened
    Alarma de fallo de alimentación Detecting an external power failure
    Detección de enlaces Envía paquetes de latidos para detectar y vuelve a marcar automáticamente cuando se desconecta.
    Vigilante integrado El dispositivo realiza una autodetección y se recupera automáticamente de los fallos de funcionamiento.
    Temperature Detection The CPU temperature can be detected and recorded in logs
  • Communication Protocol
    Acquisition Protocol IEC62056-21 Mode-C; DLMS/COSEM; Modbus RTU
    Access Platform MQTT/MQTTS/MASS/TeleMetriX Head-End
  • Gestión de redes
    Configuración Web via USB/ETH
    Mejora Local via USB/ETH; remote via FTP/InHand DM platform
    Registro Support local system log and important log power-off autosave

Datasheets

MG301_Datasheet_V1.3
10.21.2026 1.3 MB

Paquete estándar*

  • MG301 Metering Gateway *1
  • Cellular Antenna *1

*El contenido estándar del paquete varía según los códigos crder estándar.

Accesorios opcionales

  • Wall Mount Kit *1

Contáctanos Para obtener más información sobre nuestras opciones de embalaje, contáctenos directamente.

Presupuesto
  • Especificaciones técnicas clave
    Celular 4G cellular module, CAT1/CAT4
    Plataforma de hardware MIPS24KEc (575/580 MHz); 128MB RAM; 64MB Flash
    Metering Protocols IEC62056-21 Mode-C; DLMS/COSEM; Modbus RTU
    Platform Access MQTT/MQTTS/MASS/TeleMetriX Head-End
    Interfaces 2 × isolated RS485; 1 × USB2.0 Type-C; 4 × DI; 2 × DO; 2 × latching relay outputs (optional); 1 × 100Mbps Ethernet (optional)
    Fuerza 55–270 VAC, nominal 230 V; 20 VA (max.)
    Dimensiones 130 × 125 × 68 mm (specification table)
    Entorno operativo -30 to 70 °C; 0–93% ambient humidity
    Protección IP40
  • Product Interfaces
    Ethernet 1 × 100Mbps Ethernet port, RJ45 connector (optional)
    Celular 4G cellular module, CAT1/CAT4
    USB 1 × USB2.0, Type-C
    Puerto serie 2 × RS485, isolated, terminal-block connector; RS485: Data+, Data-, GND
    Tarjeta SIM Mini SIM-2FF card, supports 1.8/3V SIM/UIM card; eSIM
    Conector de antena 1 × Cellular Antenna
    Botón 1 × System reset button
    Open Lid Detection 1 × Open Cover Inspection key
    Relay Outputs 2 × relay outputs: 240VAC/5A, latching relay output (optional)
    Digital Inputs 4 × digital inputs; isolation voltage: 3500 V; dry contact: Logic 1, Open; Logic 0, Close to ground; wet contact: VIH(max.) = 30 VDC, VIH(min.) = 5 VDC, VIL(max.) = 2 VDC
    Digital Outputs 2 × digital outputs; isolation voltage: 3500 V; supply voltage: 20 V max.; sink current: 0.5 A max.
  • Plataforma de hardware
    UPC MIPS24KEc (575/580 MHz)
    RAM 128 MB
    DESTELLO 64MB
  • Interfaces
    Puerto Ethernet 1 × 100Mbps Ethernet port, RJ45 connector (optional)
    Celular 4G cellular module, CAT1/CAT4
    USB 1 × USB2.0, Type-C
    Puerto serie 2 × RS485, isolated, terminal-block connector; RS485: Data+, Data-, GND
    Tarjeta SIM Mini SIM-2FF, supports 1.8/3V SIM/UIM card; eSIM
    Conector de antena 1 × Cellular Antenna
    Botón 1 × System reset button
    Open Lid Detection Device 1 × Open Cover Inspection key
    Relay Outputs 2 × relay outputs: 240VAC/5A, latching relay output (optional)
    Digital Inputs 4 × digital inputs; isolation voltage: 3500 V; dry contact: Logic 1, Open; Logic 0, Close to ground; wet contact: VIH(max.) = 30 VDC, VIH(min.) = 5 VDC, VIL(max.) = 2 VDC
    Digital Outputs 2 × digital outputs; isolation voltage: 3500 V; supply voltage: 20 V max.; sink current: 0.5 A max.
  • Other Hardware
    RTC Real time clock operated from on-board coin-cell battery
    Punctuality Accuracy 0.5 S/day
    Batería Li-ion battery (500mAh) or supercapacitor (Li-ion battery default)
  • Fuerza
    Fuente de alimentación AC input: unregulated 55V to 270 VAC, nominal 230V, instantaneous voltage protection of 6KV; reverse voltage protection
    Consumo de energía 20VA (max.)
  • Características mecánicas
    Montaje DIN rail / mounting ear (default)
    Material de la carcasa Plástico
    Dimension 130 × 125 × 61 mm
    Protección IP40
  • Ambient Temperature and Humidity
    Temperatura de funcionamiento -30 to 70 °C
    Humedad ambiental 0–93%
    Declared Pollution Degree 3
    Overvoltage Category CAT III
  • CONDUJO
    Sistema 1 × Power, 3 × CSQ, 1 × IP, 1 × 4G, 1 × GPRS, 2 × RS485, 2 × Relay
  • Safety & EMC
    Safety & EMC IEC 62368-1; EN 55032 Class B; EN 55035 Level 3
  • Other Standards
    Otros EN 60068-2-30; EN 60068-2-31; EN 60068-2-1; EN 60068-2-2; EN 62262; IEC 60529; IEC 60695-11-10 standard V-0 class
  • Sistema operativo
    Sistema operativo Linux
  • Internet
    Access authentication APN, VPDN
    Internet access CHAP, PAP
    Network format LTE CAT 1
  • Network Protocol
    Aplicación de propiedad intelectual ICMP, DNS, TCP/UDP, TCP Server, DHCP, NTP
    Enrutamiento IP Enrutamiento estático
  • Fiabilidad
    Cover Opening Alarm Detection lid is opened
    Alarma de fallo de alimentación Detecting an external power failure
    Detección de enlaces Envía paquetes de latidos para detectar y vuelve a marcar automáticamente cuando se desconecta.
    Vigilante integrado El dispositivo realiza una autodetección y se recupera automáticamente de los fallos de funcionamiento.
    Temperature Detection The CPU temperature can be detected and recorded in logs
  • Communication Protocol
    Acquisition Protocol IEC62056-21 Mode-C; DLMS/COSEM; Modbus RTU
    Access Platform MQTT/MQTTS/MASS/TeleMetriX Head-End
  • Gestión de redes
    Configuración Web via USB/ETH
    Mejora Local via USB/ETH; remote via FTP/InHand DM platform
    Registro Support local system log and important log power-off autosave

Datasheets

MG301_Datasheet_V1.3
10.21.2026 1.3 MB

Paquete estándar*

  • MG301 Metering Gateway *1
  • Cellular Antenna *1

*El contenido estándar del paquete varía según los códigos crder estándar.

Accesorios opcionales

  • Wall Mount Kit *1

Contáctanos Para obtener más información sobre nuestras opciones de embalaje, contáctenos directamente.

Casos relacionados

Avance
Multi-Meter Remote Reading and Centralized Management for Smart Grids

Multi-Meter Remote Reading and Centralized Management for Smart Grids

MG301 connects multiple smart meters and enables remote meter reading over 4G,…

Más información →
Ver todos los casos

Preguntas frecuentes

What is MG301 designed for?

MG301 is designed for automated meter reading applications. It enables head-end systems to communicate with field meters over cellular networks, retrieve meter data, and monitor meter operating parameters.

MG301 supports IEC 62056-21 Mode C, DLMS/COSEM, and Modbus RTU. Compatibility with individual meters depends on their communication interfaces and protocol implementations.

MG301 provides two isolated RS485 ports, four digital inputs, two digital outputs, and a USB Type-C port. Ethernet and latching relay outputs are available as options.

MG301 uses link monitoring, automatic reconnection, and hardware and software watchdog mechanisms to detect communication issues and recover from interruptions.

También te puede gustar