Posez n'importe quelle question à l'IA

MG301-M
Modular MASS Modem

MG301-M is a modular cellular modem designed for automated meter reading. It plugs into compatible modular meters and connects them to head-end systems over 2G/4G networks, supporting standard metering protocols for remote data collection.

MG301-M
Modular MASS Modem

MG301-M is a modular cellular modem designed for automated meter reading. It plugs into compatible modular meters and connects them to head-end systems over 2G/4G networks, supporting standard metering protocols for remote data collection.

PHOTO

Purpose-Built for Modular Metering

indicateur de réussite de l'opération

Modular Design for Easy Integration

Designed to plug into the modem socket of compatible modular meters, enabling cellular communication without a separate external gateway.

Reliable 2G/4G Connectivity

LTE Cat.1 connectivity, automatic reconnection, and built-in watchdog mechanisms help maintain reliable communication across distributed metering sites.

modules de protocole de communication

Standard Metering Protocols

Supports IEC 62056-21 Mode C and DLMS/COSEM for communication with compatible meters and automated data collection.

Connectivité permanente

Head-End System Connectivity

Supports MASS, VIKO, TeleMetriX Head-End, and MQTT/MQTTS for data communication with compatible meter data collection systems.

Flexible Interfaces for Meter Integration

Dual RS485 ports, one digital input, and one latching relay output support connectivity and integration with metering equipment.

symbole de bouclier de sécurité

Fonctions de sécurité intégrées

AES-128 encryption, ECDHE, and authentication for sensitive serial-port operations help protect metering communications and device access.

  • Caractéristiques techniques clés
    Cellulaire 2G/4G (LTE CAT 1)
    Plateforme matérielle 2.5MB RAM; 32MB Flash
    Metering Protocols IEC62056-21 Mode-C; DLMS/COSEM
    Platform Access MQTT/MQTTS/VIKO/MASS/TeleMetriX Head-End
    Interfaces 2 × RS485; 1 × USB2.0 Type-C; 1 × digital input; 1 × relay output
    Pouvoir 12V DC ± 10%; 6W (MAX)
    Dimensions 114 × 74.4 × 45 mm
    Environnement d'exploitation -30 to 70 °C; 0–93% ambient humidity
    Protection IP40
  • Product Interfaces
    Cellulaire 2G/4G (LTE CAT 1)
    USB 1 × USB2.0, Type-C
    Port série 2 × RS485; RS485: Data+, Data-, GND
    Carte SIM Mini SIM-2FF card, supports 1.8/3V SIM/UIM card
    Connecteur d'antenne 1 × Cellular Antenna
    Bouton 1 × System reset button
    Entrée numérique 1 × digital input; dry contact: Logic 0, Open; Logic 1, Close
    Relay Output 1 × relay output: 240VAC/5A, latching relay
  • Plateforme matérielle
    BÉLIER 2.5MB
    ÉCLAIR 32MB
  • Interfaces
    Cellulaire 2G/4G (LTE CAT 1)
    USB 1 × USB2.0, Type-C
    Port série 2 × RS485; RS485: Data+, Data-, GND
    Carte SIM Mini SIM-2FF card, supports 1.8/3V SIM/UIM card
    Connecteur d'antenne 1 × Cellular Antenna
    Bouton 1 × System reset button
    E/S numériques 1 × digital input: Dry contact: Logic 0, Open; Logic 1, Close; 1 × relay output: 240VAC/5A, Latching Relay
  • Other Hardware
    RTC Real time clock operated from on-board coin-cell battery
    Punctuality Accuracy 0.5S / day
    Batterie Li-ion Battery, 300mAh, rechargeable and replaceable.
  • Pouvoir
    Alimentation 12V DC ± 10%
    Consommation d'énergie 6W (MAX)
  • Caractéristiques mécaniques
    Montage Plug to the modem socket of the modular meters
    Matériau de l'enveloppe Plastique
    Dimension 114 × 74.4 × 45 mm
    Protection IP40
  • Ambient Temperature and Humidity
    Operation Temperature -30 ~ 70℃
    Humidité ambiante 0–93%
    Declared Degree of Contamination 3
    Overvoltage Category CAT III
    Electrical Protection Class II
  • DIRIGÉ
    Système 1 × Power, 3 × CSQ, 1 × IP, 1 × 2G/4G, 2 × RS485, 1 × Relay
  • Safety & EMC
    Safety & EMC IEC 62368-1; EN 55032, Class B; EN 55035, Level 2
  • Other Standards
    Autres EN 60068-2-30; EN 60068-2-31; EN 60068-2-1; EN 60068-2-2; EN 62262; IEC 60529; IEC 60695-11-10 standard V-0 class
  • Système opérateur
    Système d'exploitation RTOS
  • Internet
    Access authentication APN, VPDN
    Internet access CHAP, PAP
    Network format 2G/4G (LTE CAT 1)
    eSIM Support eSIM (LPA)
  • Network Protocol
    Demande de propriété intellectuelle ICMP, DNS, TCP/UDP, TCP Server, DHCP, NTP
  • Fiabilité
    Alarme de panne de courant Detecting an external power failure
    Détection de liens Envoie des paquets de pulsation pour détecter la connexion, recomposition automatique en cas de déconnexion.
    Chien de garde intégré L'appareil effectue une autodétection et se rétablit automatiquement en cas de dysfonctionnement.
    Temperature Detection The CPU temperature can be detected and recorded in logs
  • Communication Protocol
    Acquisition Protocol IEC62056-21 Mode-C; DLMS/COSEM
    Access Platform MQTT/MQTTS/VIKO/MASS/TeleMetriX Head-End
  • Sécurité
    Cryptage AES-128 and ECDHE
    Authentification In cases where configuration changes, software updates, or connection to the control center are made via the modem's serial ports, authentication will be performed between the modem and the device attempting to connect to it. A log will be kept for these operations.
  • Gestion de réseau
    Configuration Web Via USB
    Mise à niveau Local Via USB, Remote Via FTP/InHand DM platform (Coming soon)
    Enregistrer Support local system log and important log power-off autosave

Fiches techniques

FV680_Datasheet_V1.0
7.28.2026 1.6 MB
FV680-PS02 product Datasheet_V1.0
6.11.2026 1.6 MB
FV700-PS01 product specificationsV1.3.pdf
2.8.2025 859.5 KB
AE510 Smart Kit SpecificationsV1.0.pdf
10.25.2024 1.1 MB

Flyers

AI VENDING COOLER-241120.pdf
11.20.2024 7.5 MB

Forfait standard*

  • MG301-M Modular Metering Gateway *1

*Le contenu des emballages standard varie selon les codes de crédit standard.

Contactez-nous directement pour en savoir plus sur nos options d'emballage.

Caractéristiques
  • Caractéristiques techniques clés
    Cellulaire 2G/4G (LTE CAT 1)
    Plateforme matérielle 2.5MB RAM; 32MB Flash
    Metering Protocols IEC62056-21 Mode-C; DLMS/COSEM
    Platform Access MQTT/MQTTS/VIKO/MASS/TeleMetriX Head-End
    Interfaces 2 × RS485; 1 × USB2.0 Type-C; 1 × digital input; 1 × relay output
    Pouvoir 12V DC ± 10%; 6W (MAX)
    Dimensions 114 × 74.4 × 45 mm
    Environnement d'exploitation -30 to 70 °C; 0–93% ambient humidity
    Protection IP40
  • Product Interfaces
    Cellulaire 2G/4G (LTE CAT 1)
    USB 1 × USB2.0, Type-C
    Port série 2 × RS485; RS485: Data+, Data-, GND
    Carte SIM Mini SIM-2FF card, supports 1.8/3V SIM/UIM card
    Connecteur d'antenne 1 × Cellular Antenna
    Bouton 1 × System reset button
    Entrée numérique 1 × digital input; dry contact: Logic 0, Open; Logic 1, Close
    Relay Output 1 × relay output: 240VAC/5A, latching relay
  • Plateforme matérielle
    BÉLIER 2.5MB
    ÉCLAIR 32MB
  • Interfaces
    Cellulaire 2G/4G (LTE CAT 1)
    USB 1 × USB2.0, Type-C
    Port série 2 × RS485; RS485: Data+, Data-, GND
    Carte SIM Mini SIM-2FF card, supports 1.8/3V SIM/UIM card
    Connecteur d'antenne 1 × Cellular Antenna
    Bouton 1 × System reset button
    E/S numériques 1 × digital input: Dry contact: Logic 0, Open; Logic 1, Close; 1 × relay output: 240VAC/5A, Latching Relay
  • Other Hardware
    RTC Real time clock operated from on-board coin-cell battery
    Punctuality Accuracy 0.5S / day
    Batterie Li-ion Battery, 300mAh, rechargeable and replaceable.
  • Pouvoir
    Alimentation 12V DC ± 10%
    Consommation d'énergie 6W (MAX)
  • Caractéristiques mécaniques
    Montage Plug to the modem socket of the modular meters
    Matériau de l'enveloppe Plastique
    Dimension 114 × 74.4 × 45 mm
    Protection IP40
  • Ambient Temperature and Humidity
    Operation Temperature -30 ~ 70℃
    Humidité ambiante 0–93%
    Declared Degree of Contamination 3
    Overvoltage Category CAT III
    Electrical Protection Class II
  • DIRIGÉ
    Système 1 × Power, 3 × CSQ, 1 × IP, 1 × 2G/4G, 2 × RS485, 1 × Relay
  • Safety & EMC
    Safety & EMC IEC 62368-1; EN 55032, Class B; EN 55035, Level 2
  • Other Standards
    Autres EN 60068-2-30; EN 60068-2-31; EN 60068-2-1; EN 60068-2-2; EN 62262; IEC 60529; IEC 60695-11-10 standard V-0 class
  • Système opérateur
    Système d'exploitation RTOS
  • Internet
    Access authentication APN, VPDN
    Internet access CHAP, PAP
    Network format 2G/4G (LTE CAT 1)
    eSIM Support eSIM (LPA)
  • Network Protocol
    Demande de propriété intellectuelle ICMP, DNS, TCP/UDP, TCP Server, DHCP, NTP
  • Fiabilité
    Alarme de panne de courant Detecting an external power failure
    Détection de liens Envoie des paquets de pulsation pour détecter la connexion, recomposition automatique en cas de déconnexion.
    Chien de garde intégré L'appareil effectue une autodétection et se rétablit automatiquement en cas de dysfonctionnement.
    Temperature Detection The CPU temperature can be detected and recorded in logs
  • Communication Protocol
    Acquisition Protocol IEC62056-21 Mode-C; DLMS/COSEM
    Access Platform MQTT/MQTTS/VIKO/MASS/TeleMetriX Head-End
  • Sécurité
    Cryptage AES-128 and ECDHE
    Authentification In cases where configuration changes, software updates, or connection to the control center are made via the modem's serial ports, authentication will be performed between the modem and the device attempting to connect to it. A log will be kept for these operations.
  • Gestion de réseau
    Configuration Web Via USB
    Mise à niveau Local Via USB, Remote Via FTP/InHand DM platform (Coming soon)
    Enregistrer Support local system log and important log power-off autosave

Fiches techniques

FV680_Datasheet_V1.0
7.28.2026 1.6 MB
FV680-PS02 product Datasheet_V1.0
6.11.2026 1.6 MB
FV700-PS01 product specificationsV1.3.pdf
2.8.2025 859.5 KB
AE510 Smart Kit SpecificationsV1.0.pdf
10.25.2024 1.1 MB

Flyers

AI VENDING COOLER-241120.pdf
11.20.2024 7.5 MB

Forfait standard*

  • MG301-M Modular Metering Gateway *1

*Le contenu des emballages standard varie selon les codes de crédit standard.

Contactez-nous directement pour en savoir plus sur nos options d'emballage.

Cas connexes

Aperçu
Déploiement de distributeurs automatiques de réfrigérateurs à intelligence artificielle

Déploiement de distributeurs automatiques de réfrigérateurs à intelligence artificielle

Déploiement d'applications et de cas de refroidisseurs distributeurs automatiques basés sur l'IA : principaux enseignements…

En savoir plus →
Voir tous les cas

Foire aux questions

What is MG301-M designed for?

MG301-M is a modular cellular modem designed for automated meter reading applications. It connects compatible modular meters to head-end systems over cellular networks, enabling remote meter data collection and monitoring.

MG301-M is designed to plug directly into the modem socket of compatible modular meters, while MG301 is a standalone metering gateway. The two products also differ in their interfaces, power requirements, and supported protocols.

MG301-M supports IEC 62056-21 Mode C and DLMS/COSEM, enabling communication with meters that use these protocols.

MG301-M supports 2G and 4G LTE Cat.1 cellular connectivity. It also features automatic link detection, reconnection, and watchdog mechanisms to improve communication reliability.

Vous aimerez peut-être aussi