MG301
4G Metering Gateway
MG301 is a cellular gateway designed for automated meter reading. It connects field meters to head-end systems over 4G networks, supporting multiple metering protocols, flexible interfaces, and reliable remote communication.
MG301
4G Metering Gateway
MG301 is a cellular gateway designed for automated meter reading. It connects field meters to head-end systems over 4G networks, supporting multiple metering protocols, flexible interfaces, and reliable remote communication.
PHOTO
Built for Reliable Remote Meter Reading
Reliable 4G Connectivity
LTE Cat.1/Cat.4 options, automatic link recovery, and built-in watchdog mechanisms help maintain reliable communication across distributed metering sites.
Multiple Metering Protocols
Supports IEC 62056-21 Mode C, DLMS/COSEM, and Modbus RTU for communication with a wide range of compatible meters.
Flexible Interfaces for Field Integration
Dual isolated RS485 ports and built-in digital I/O support diverse field connections, with Ethernet and relay outputs available as options.
Head-End System Integration
Supports MQTT/MQTTS, MASS, and TeleMetriX Head-End protocols for data communication with compatible meter data collection systems.
Event Detection & Remote Maintenance
Power failure and enclosure-opening detection help identify field issues, while remote firmware upgrades simplify ongoing maintenance.
Industrial-Grade Design
Wide-range 55–270 VAC input, -30°C to 70°C operation, and Li-ion battery or supercapacitor options support deployment in demanding electrical environments.
-
Key Technical Specifications
Cellular 4G cellular module, CAT1/CAT4Hardware Platform MIPS24KEc (575/580 MHz); 128MB RAM; 64MB FlashMetering Protocols IEC62056-21 Mode-C; DLMS/COSEM; Modbus RTUPlatform Access MQTT/MQTTS/MASS/TeleMetriX Head-EndInterfaces 2 × isolated RS485; 1 × USB2.0 Type-C; 4 × DI; 2 × DO; 2 × latching relay outputs (optional); 1 × 100Mbps Ethernet (optional)Power 55–270 VAC, nominal 230 V; 20 VA (max.)Dimensions 130 × 125 × 68 mm (specification table)Operating Environment -30 to 70 °C; 0–93% ambient humidityProtection IP40
-
Product Interfaces
Ethernet 1 × 100Mbps Ethernet port, RJ45 connector (optional)Cellular 4G cellular module, CAT1/CAT4USB 1 × USB2.0, Type-CSerial Port 2 × RS485, isolated, terminal-block connector; RS485: Data+, Data-, GNDSIM Card Mini SIM-2FF card, supports 1.8/3V SIM/UIM card; eSIMAntenna Connector 1 × Cellular AntennaButton 1 × System reset buttonOpen Lid Detection 1 × Open Cover Inspection keyRelay Outputs 2 × relay outputs: 240VAC/5A, latching relay output (optional)Digital Inputs 4 × digital inputs; isolation voltage: 3500 V; dry contact: Logic 1, Open; Logic 0, Close to ground; wet contact: VIH(max.) = 30 VDC, VIH(min.) = 5 VDC, VIL(max.) = 2 VDCDigital Outputs 2 × digital outputs; isolation voltage: 3500 V; supply voltage: 20 V max.; sink current: 0.5 A max.
-
Hardware Platform
CPU MIPS24KEc (575/580 MHz)RAM 128MBFLASH 64MB
-
Interfaces
Ethernet Port 1 × 100Mbps Ethernet port, RJ45 connector (optional)Cellular 4G cellular module, CAT1/CAT4USB 1 × USB2.0, Type-CSerial Port 2 × RS485, isolated, terminal-block connector; RS485: Data+, Data-, GNDSIM Card Mini SIM-2FF, supports 1.8/3V SIM/UIM card; eSIMAntenna Connector 1 × Cellular AntennaButton 1 × System reset buttonOpen Lid Detection Device 1 × Open Cover Inspection keyRelay Outputs 2 × relay outputs: 240VAC/5A, latching relay output (optional)Digital Inputs 4 × digital inputs; isolation voltage: 3500 V; dry contact: Logic 1, Open; Logic 0, Close to ground; wet contact: VIH(max.) = 30 VDC, VIH(min.) = 5 VDC, VIL(max.) = 2 VDCDigital Outputs 2 × digital outputs; isolation voltage: 3500 V; supply voltage: 20 V max.; sink current: 0.5 A max.
-
Other Hardware
RTC Real time clock operated from on-board coin-cell batteryPunctuality Accuracy 0.5 S/dayBattery Li-ion battery (500mAh) or supercapacitor (Li-ion battery default)
-
Power
Power Supply AC input: unregulated 55V to 270 VAC, nominal 230V, instantaneous voltage protection of 6KV; reverse voltage protectionPower Consumption 20VA (max.)
-
Mechanical Characteristics
Mounting DIN rail / mounting ear (default)Enclosure Material PlasticDimension 130 × 125 × 61 mmProtection IP40
-
Ambient Temperature and Humidity
Operating Temperature -30 to 70 °CAmbient Humidity 0–93%Declared Pollution Degree 3Overvoltage Category CAT III
-
LED
System 1 × Power, 3 × CSQ, 1 × IP, 1 × 4G, 1 × GPRS, 2 × RS485, 2 × Relay
-
Safety & EMC
Safety & EMC IEC 62368-1; EN 55032 Class B; EN 55035 Level 3
-
Other Standards
Others EN 60068-2-30; EN 60068-2-31; EN 60068-2-1; EN 60068-2-2; EN 62262; IEC 60529; IEC 60695-11-10 standard V-0 class
-
Operating System
OS Linux
-
Internet
Access authentication APN, VPDNInternet access CHAP, PAPNetwork format LTE CAT 1
-
Network Protocol
IP Application ICMP, DNS, TCP/UDP, TCP Server, DHCP, NTPIP Routing Static routing
-
Reliability
Cover Opening Alarm Detection lid is openedPower Failure Alarm Detecting an external power failureLink Detection Sends heartbeat packets to detect, auto redials when disconnectedEmbedded Watchdog Device runs self-detection, auto recovers from malfunctionsTemperature Detection The CPU temperature can be detected and recorded in logs
-
Communication Protocol
Acquisition Protocol IEC62056-21 Mode-C; DLMS/COSEM; Modbus RTUAccess Platform MQTT/MQTTS/MASS/TeleMetriX Head-End
-
Network Management
Configuration Web via USB/ETHUpgrade Local via USB/ETH; remote via FTP/InHand DM platformLog Support local system log and important log power-off autosave
Datasheets
Standard package*
- MG301 Metering Gateway *1
- Cellular Antenna *1
*Standard package contents vary by standard crder codes.
Optional accessories
- Wall Mount Kit *1
Contact us directly to learn more about our packaging options.
Specifications
-
Key Technical Specifications
Cellular 4G cellular module, CAT1/CAT4Hardware Platform MIPS24KEc (575/580 MHz); 128MB RAM; 64MB FlashMetering Protocols IEC62056-21 Mode-C; DLMS/COSEM; Modbus RTUPlatform Access MQTT/MQTTS/MASS/TeleMetriX Head-EndInterfaces 2 × isolated RS485; 1 × USB2.0 Type-C; 4 × DI; 2 × DO; 2 × latching relay outputs (optional); 1 × 100Mbps Ethernet (optional)Power 55–270 VAC, nominal 230 V; 20 VA (max.)Dimensions 130 × 125 × 68 mm (specification table)Operating Environment -30 to 70 °C; 0–93% ambient humidityProtection IP40
-
Product Interfaces
Ethernet 1 × 100Mbps Ethernet port, RJ45 connector (optional)Cellular 4G cellular module, CAT1/CAT4USB 1 × USB2.0, Type-CSerial Port 2 × RS485, isolated, terminal-block connector; RS485: Data+, Data-, GNDSIM Card Mini SIM-2FF card, supports 1.8/3V SIM/UIM card; eSIMAntenna Connector 1 × Cellular AntennaButton 1 × System reset buttonOpen Lid Detection 1 × Open Cover Inspection keyRelay Outputs 2 × relay outputs: 240VAC/5A, latching relay output (optional)Digital Inputs 4 × digital inputs; isolation voltage: 3500 V; dry contact: Logic 1, Open; Logic 0, Close to ground; wet contact: VIH(max.) = 30 VDC, VIH(min.) = 5 VDC, VIL(max.) = 2 VDCDigital Outputs 2 × digital outputs; isolation voltage: 3500 V; supply voltage: 20 V max.; sink current: 0.5 A max.
-
Hardware Platform
CPU MIPS24KEc (575/580 MHz)RAM 128MBFLASH 64MB
-
Interfaces
Ethernet Port 1 × 100Mbps Ethernet port, RJ45 connector (optional)Cellular 4G cellular module, CAT1/CAT4USB 1 × USB2.0, Type-CSerial Port 2 × RS485, isolated, terminal-block connector; RS485: Data+, Data-, GNDSIM Card Mini SIM-2FF, supports 1.8/3V SIM/UIM card; eSIMAntenna Connector 1 × Cellular AntennaButton 1 × System reset buttonOpen Lid Detection Device 1 × Open Cover Inspection keyRelay Outputs 2 × relay outputs: 240VAC/5A, latching relay output (optional)Digital Inputs 4 × digital inputs; isolation voltage: 3500 V; dry contact: Logic 1, Open; Logic 0, Close to ground; wet contact: VIH(max.) = 30 VDC, VIH(min.) = 5 VDC, VIL(max.) = 2 VDCDigital Outputs 2 × digital outputs; isolation voltage: 3500 V; supply voltage: 20 V max.; sink current: 0.5 A max.
-
Other Hardware
RTC Real time clock operated from on-board coin-cell batteryPunctuality Accuracy 0.5 S/dayBattery Li-ion battery (500mAh) or supercapacitor (Li-ion battery default)
-
Power
Power Supply AC input: unregulated 55V to 270 VAC, nominal 230V, instantaneous voltage protection of 6KV; reverse voltage protectionPower Consumption 20VA (max.)
-
Mechanical Characteristics
Mounting DIN rail / mounting ear (default)Enclosure Material PlasticDimension 130 × 125 × 61 mmProtection IP40
-
Ambient Temperature and Humidity
Operating Temperature -30 to 70 °CAmbient Humidity 0–93%Declared Pollution Degree 3Overvoltage Category CAT III
-
LED
System 1 × Power, 3 × CSQ, 1 × IP, 1 × 4G, 1 × GPRS, 2 × RS485, 2 × Relay
-
Safety & EMC
Safety & EMC IEC 62368-1; EN 55032 Class B; EN 55035 Level 3
-
Other Standards
Others EN 60068-2-30; EN 60068-2-31; EN 60068-2-1; EN 60068-2-2; EN 62262; IEC 60529; IEC 60695-11-10 standard V-0 class
-
Operating System
OS Linux
-
Internet
Access authentication APN, VPDNInternet access CHAP, PAPNetwork format LTE CAT 1
-
Network Protocol
IP Application ICMP, DNS, TCP/UDP, TCP Server, DHCP, NTPIP Routing Static routing
-
Reliability
Cover Opening Alarm Detection lid is openedPower Failure Alarm Detecting an external power failureLink Detection Sends heartbeat packets to detect, auto redials when disconnectedEmbedded Watchdog Device runs self-detection, auto recovers from malfunctionsTemperature Detection The CPU temperature can be detected and recorded in logs
-
Communication Protocol
Acquisition Protocol IEC62056-21 Mode-C; DLMS/COSEM; Modbus RTUAccess Platform MQTT/MQTTS/MASS/TeleMetriX Head-End
-
Network Management
Configuration Web via USB/ETHUpgrade Local via USB/ETH; remote via FTP/InHand DM platformLog Support local system log and important log power-off autosave
Downloads
Datasheets
Ordering
Standard package*
- MG301 Metering Gateway *1
- Cellular Antenna *1
*Standard package contents vary by standard crder codes.
Optional accessories
- Wall Mount Kit *1
Contact us directly to learn more about our packaging options.
Related Cases
Multi-Meter Remote Reading and Centralized Management for Smart Grids
MG301 connects multiple smart meters and enables remote meter reading over 4G,…
Learn More →Frequently Asked Questions
What is MG301 designed for?
MG301 is designed for automated meter reading applications. It enables head-end systems to communicate with field meters over cellular networks, retrieve meter data, and monitor meter operating parameters.
What metering protocols does MG301 support?
MG301 supports IEC 62056-21 Mode C, DLMS/COSEM, and Modbus RTU. Compatibility with individual meters depends on their communication interfaces and protocol implementations.
What interfaces are available on MG301?
MG301 provides two isolated RS485 ports, four digital inputs, two digital outputs, and a USB Type-C port. Ethernet and latching relay outputs are available as options.
How does MG301 maintain communication reliability?
MG301 uses link monitoring, automatic reconnection, and hardware and software watchdog mechanisms to detect communication issues and recover from interruptions.