Ask AI Anything

IG902
High-performance
Edge Gateway

IG902 targets complex industrial sites with enhanced compute and rich interfaces. Optional DSA and Python/Docker extensibility support multi-source acquisition and higher-throughput edge workloads.

IG902
High-performance
Edge Gateway

IG902 targets complex industrial sites with enhanced compute and rich interfaces. Optional DSA and Python/Docker extensibility support multi-source acquisition and higher-throughput edge workloads.

PHOTO

Stronger Compute, Faster Industrial Response

Optional DSA, 80+ protocols
Normalized data handling shortens integration and reduces
High-performance platform
Compute/storage support pre-processing, rule evaluation, bridging and lightweight analytics for faster response.
GbE + industrial serial ports
Mixed Ethernet and serial connectivity supports aggregation of diverse field endpoints.
Built-in multi-link redundancy
Backup across links and failover with link checks improve availability and recovery speed.
Python/Docker extensibility
Supports custom logic and containerized delivery for rapid on-site customization.
Industrial-grade rugged design
Fanless industrial design ensures long-term stability and easier maintenance.
  • Core Technical Specifications
    Cellular Network LTE Cat.4/Cat.6 (model dependent)
    Network Features APN, VPDN, CHAP/PAP/MS-CHAP/MS-CHAPV2; DHCP Server/Relay/Client; DNS Relay; DDNS; static routing
    Security SPI firewall, ACL, NAT/PAT/DMZ, AAA (Local/Radius/Tacacs+/LDAP), IPsec/GRE/L2TP/OpenVPN/CA
    Cloud Management DeviceLive remote configuration, upgrades, and operations
    Secondary Development Python and Docker secondary development
    Data Acquisition Protocols Modbus RTU/TCP, EtherNet/IP, OPC UA, IEC101/104, DNP3.0, BACnet, CNC
    Processor and Memory ARM Cortex-A8 @1GHz, 1GB DDR3
    Storage 8GB eMMC, microSD up to 32GB
    Ethernet Ports 2 × 10/100/1000 Mbps
    Serial and I/O 1×RS-232/RS-485 + 1×RS-485 (2×RS-485 on some models); optional 4DI+4DO or 4DI+3DO+1 relay
    Power Supply 12~48V DC, reverse polarity and overcurrent protection
    Operating Temperature and Protection -25 °C ~ 70 °C (-13 °F ~ 158 °F), IP30
  • CPU and Storage
    CPU ARM Cortex-A8 @1GHz
    RAM IG902-B: 512MB DDR3 IG902-H: 1GB DDR3 RAM
    Flash 8GB eMMC
  • Connectivity and Interfaces
    Ethernet Ports 2×10/100/1000 Mbps Ethernet ports (WAN/LAN or 2×LAN)
    I/O Ports None / 4×DI + 3×DO + 1×Relay output DO or digital/pulse output DO (isolated)
    Serial Ports 1×RS-232/RS-485 + 1×RS-485
    SIM Card Slot 1.8V/3V, 2×drawer-type slot
    LED Indicators POWER, STATUS, WARN, ERROR, MODEM, SIM1, SIM2, microSD, PYTHON, USER1, USER2, Wi-Fi, GPS, SIGNAL
    Console Port 1×console RS-232 (RJ45)
    USB Port 1×USB 2.0 port
    microSD microSD expansion up to 32GB
    Wi-Fi(optional) 2.4G/5G Wi-Fi (802.11 ac/a/b/g/n)
    GNSS(optional) GPS and BeiDou
    Reset Button Pinhole button
  • Power and Power Consumption
    Power Input 12~48V DC input
    Power Terminal Unpluggable industrial terminal
    Reverse Polarity/Overcurrent Protection Supported
  • Mechanical Specifications
    Mounting Method DIN-rail/wall mounting
    Protection Rating IP30
    Housing and Cooling Metal housing, fanless
    RTC (Optional) Embedded RTC powered by super capacitor
  • Environment and Certifications
    Storage Temperature -40 °C ~ 85 °C (-40 °F ~ 185 °F)
    Operating Temperature -25 °C ~ 70 °C (-13 °F ~ 158 °F)
    Ambient Humidity 5~95% RH non-condensing
    Physical Characteristics IEC60068-2-27 shock resistance IEC60068-2-6 vibration resistance IEC60068-2-32 drop resistance
    EMC Standard EN61000-4-2, level 3, Static EN61000-4-3, level 3, Radiation Electric Field EN61000-4-4, level 3, Pulsed Electric Field EN61000-4-5, level 3, Surge EN61000-4-6, level 3, Conducted Distubance Immunity EN61000-4-8, Power Frequency Field Resistance, horizontal / vertical 400A/m (>level 3) EN61000-4-12, level 3, Shock Wave Resistance
    Certifications CE,FCC, PTCRB, RCM, IC, IMDA, AT&T, MIC&JATE, MSIP, EAC,ANATEL, UKCA
  • Software Specifications
    Operating System Custom Linux
  • Network Features
    Network Access APN, VPDN
    Access Authentication CHAP/PAP/MS-CHAP/MS-CHAPV2
    Network Type LTE, WCDMA(HSPA+), EDGE, GPRS, CDMA
    LAN Protocols ARP, EtherNet
    IP Applications Ping, Traceroute, DHCP Server/Relay/Client, DNS Relay, DDNS, Telnet, SSH, HTTP, HTTPS, TFTP, FTP, SFTP
    IP Routing Static routing
  • Security
    User Management Multi-level users
    Network Security SPI firewall, anti-DoS attack, multicast/ping filter, ACL, NAT, PAT, DMZ, port mapping, virtual server
    Data security IPsec VPN, GRE, L2TP, OpenVPN, CA
    CA Certificates Supported (may auto apply)
    AAA (Authentication, Authorization, Accounting) Local/Radius/Tacacs+/LDAP
  • Reliability
    Link Detection Heartbeat packet detection, auto-recovery of disconnection
    Embedded Watchdog Device self-diagnosis, auto-recovery from operation faults
    Backup Mechanism VRRP, interface backup
    Dual-SIM Switching Dual-SIM backup
  • WLAN (Optional)
    WLAN Standard IEEE 802.11 ac/a/b/g/n
    WLAN Security Open System, Shared Key, WPA/WPA2, WEP/TKIP/AES encryption
    WLAN Mode AP, Client modes
  • Open Platform and Data Acquisition Protocols (DSA)
    Python Secondary Development Secondary development platform with Python and Docker
    IoT Platform Microsoft Azure, Amazon AWS, Alibaba Cloud, etc.
    Industrial Protocols Modbus RTU Master/Slave, Modbus TCP Master/Slave, EtherNet/IP, ISO on TCP, OPC UA Client/Server, Mitsubishi MC 3C/3E/3C OverTCP, Mitsubishi CPU Port, FINSUDP, HostLink, PPI
    Electricity Protocols DLT645-2007, IEC101/104, DNP3.0
    Other Protocols BACnet, CNC
  • Network Management
    Configuration Methods Local/remote HTTP/HTTPS/Telnet/SSH config
    Upgrade Methods WEB/DeviceLive/TFTP/FTP/SFTP upgrades
    Log Local or remote log export, power-down log saving
    Remote management DeviceLive-based remote access and remote batch device management
    Network Diagnostics Ping, Traceroute, Sniffer (network packet capture tool)
Fetching resources...

Standard package*

  • IG902 Edge Gateway *1
  • 4G Antenna *1
  • Wi-Fi Antenna *1
  • GNSS Antenna *1
  • Ethernet Cable *1
  • Power Terminal *1
  • Optional accessories
  • Power Supply *1

* Standard package contents vary by standard order codes.

Contact us directly to learn more about our packaging options.

Specifications
  • Core Technical Specifications
    Cellular Network LTE Cat.4/Cat.6 (model dependent)
    Network Features APN, VPDN, CHAP/PAP/MS-CHAP/MS-CHAPV2; DHCP Server/Relay/Client; DNS Relay; DDNS; static routing
    Security SPI firewall, ACL, NAT/PAT/DMZ, AAA (Local/Radius/Tacacs+/LDAP), IPsec/GRE/L2TP/OpenVPN/CA
    Cloud Management DeviceLive remote configuration, upgrades, and operations
    Secondary Development Python and Docker secondary development
    Data Acquisition Protocols Modbus RTU/TCP, EtherNet/IP, OPC UA, IEC101/104, DNP3.0, BACnet, CNC
    Processor and Memory ARM Cortex-A8 @1GHz, 1GB DDR3
    Storage 8GB eMMC, microSD up to 32GB
    Ethernet Ports 2 × 10/100/1000 Mbps
    Serial and I/O 1×RS-232/RS-485 + 1×RS-485 (2×RS-485 on some models); optional 4DI+4DO or 4DI+3DO+1 relay
    Power Supply 12~48V DC, reverse polarity and overcurrent protection
    Operating Temperature and Protection -25 °C ~ 70 °C (-13 °F ~ 158 °F), IP30
  • CPU and Storage
    CPU ARM Cortex-A8 @1GHz
    RAM IG902-B: 512MB DDR3 IG902-H: 1GB DDR3 RAM
    Flash 8GB eMMC
  • Connectivity and Interfaces
    Ethernet Ports 2×10/100/1000 Mbps Ethernet ports (WAN/LAN or 2×LAN)
    I/O Ports None / 4×DI + 3×DO + 1×Relay output DO or digital/pulse output DO (isolated)
    Serial Ports 1×RS-232/RS-485 + 1×RS-485
    SIM Card Slot 1.8V/3V, 2×drawer-type slot
    LED Indicators POWER, STATUS, WARN, ERROR, MODEM, SIM1, SIM2, microSD, PYTHON, USER1, USER2, Wi-Fi, GPS, SIGNAL
    Console Port 1×console RS-232 (RJ45)
    USB Port 1×USB 2.0 port
    microSD microSD expansion up to 32GB
    Wi-Fi(optional) 2.4G/5G Wi-Fi (802.11 ac/a/b/g/n)
    GNSS(optional) GPS and BeiDou
    Reset Button Pinhole button
  • Power and Power Consumption
    Power Input 12~48V DC input
    Power Terminal Unpluggable industrial terminal
    Reverse Polarity/Overcurrent Protection Supported
  • Mechanical Specifications
    Mounting Method DIN-rail/wall mounting
    Protection Rating IP30
    Housing and Cooling Metal housing, fanless
    RTC (Optional) Embedded RTC powered by super capacitor
  • Environment and Certifications
    Storage Temperature -40 °C ~ 85 °C (-40 °F ~ 185 °F)
    Operating Temperature -25 °C ~ 70 °C (-13 °F ~ 158 °F)
    Ambient Humidity 5~95% RH non-condensing
    Physical Characteristics IEC60068-2-27 shock resistance IEC60068-2-6 vibration resistance IEC60068-2-32 drop resistance
    EMC Standard EN61000-4-2, level 3, Static EN61000-4-3, level 3, Radiation Electric Field EN61000-4-4, level 3, Pulsed Electric Field EN61000-4-5, level 3, Surge EN61000-4-6, level 3, Conducted Distubance Immunity EN61000-4-8, Power Frequency Field Resistance, horizontal / vertical 400A/m (>level 3) EN61000-4-12, level 3, Shock Wave Resistance
    Certifications CE,FCC, PTCRB, RCM, IC, IMDA, AT&T, MIC&JATE, MSIP, EAC,ANATEL, UKCA
  • Software Specifications
    Operating System Custom Linux
  • Network Features
    Network Access APN, VPDN
    Access Authentication CHAP/PAP/MS-CHAP/MS-CHAPV2
    Network Type LTE, WCDMA(HSPA+), EDGE, GPRS, CDMA
    LAN Protocols ARP, EtherNet
    IP Applications Ping, Traceroute, DHCP Server/Relay/Client, DNS Relay, DDNS, Telnet, SSH, HTTP, HTTPS, TFTP, FTP, SFTP
    IP Routing Static routing
  • Security
    User Management Multi-level users
    Network Security SPI firewall, anti-DoS attack, multicast/ping filter, ACL, NAT, PAT, DMZ, port mapping, virtual server
    Data security IPsec VPN, GRE, L2TP, OpenVPN, CA
    CA Certificates Supported (may auto apply)
    AAA (Authentication, Authorization, Accounting) Local/Radius/Tacacs+/LDAP
  • Reliability
    Link Detection Heartbeat packet detection, auto-recovery of disconnection
    Embedded Watchdog Device self-diagnosis, auto-recovery from operation faults
    Backup Mechanism VRRP, interface backup
    Dual-SIM Switching Dual-SIM backup
  • WLAN (Optional)
    WLAN Standard IEEE 802.11 ac/a/b/g/n
    WLAN Security Open System, Shared Key, WPA/WPA2, WEP/TKIP/AES encryption
    WLAN Mode AP, Client modes
  • Open Platform and Data Acquisition Protocols (DSA)
    Python Secondary Development Secondary development platform with Python and Docker
    IoT Platform Microsoft Azure, Amazon AWS, Alibaba Cloud, etc.
    Industrial Protocols Modbus RTU Master/Slave, Modbus TCP Master/Slave, EtherNet/IP, ISO on TCP, OPC UA Client/Server, Mitsubishi MC 3C/3E/3C OverTCP, Mitsubishi CPU Port, FINSUDP, HostLink, PPI
    Electricity Protocols DLT645-2007, IEC101/104, DNP3.0
    Other Protocols BACnet, CNC
  • Network Management
    Configuration Methods Local/remote HTTP/HTTPS/Telnet/SSH config
    Upgrade Methods WEB/DeviceLive/TFTP/FTP/SFTP upgrades
    Log Local or remote log export, power-down log saving
    Remote management DeviceLive-based remote access and remote batch device management
    Network Diagnostics Ping, Traceroute, Sniffer (network packet capture tool)
Fetching resources...

Standard package*

  • IG902 Edge Gateway *1
  • 4G Antenna *1
  • Wi-Fi Antenna *1
  • GNSS Antenna *1
  • Ethernet Cable *1
  • Power Terminal *1
  • Optional accessories
  • Power Supply *1

* Standard package contents vary by standard order codes.

Contact us directly to learn more about our packaging options.

DeviceLive

IoT Device Management Platform

Device management, remote monitoring, edge app management, and remote maintenance to help industrial enterprises build intelligent edge networks.

DeviceLive

Related Cases

Preview
Remote Monitoring of Urban Heat Supply System

Remote Monitoring of Urban Heat Supply System

Remote Monitoring of Urban Heat Supply System Applications and Cases Key Takeaways…

Learn More →
Remote Monitoring of Hydraulic Press

Remote Monitoring of Hydraulic Press

Remote Monitoring of Hydraulic Press Applications and Cases Key Takeaways Remote Monitoring…

Learn More →
CNC Machines Remote Monitoring

CNC Machines Remote Monitoring

CNC Machines Remote Monitoring Applications and Cases Key Takeaways Remote Monitoring of…

Learn More →
Automated Production Line for Beverage

Automated Production Line for Beverage

Automated Production Line for Beverage Applications and Cases Key Takeaways Automated Production…

Learn More →
Remote Monitoring of Bearings

Remote Monitoring of Bearings

Remote Monitoring of Bearings Applications and Cases Key Takeaways Remote Monitoring of…

Learn More →
Remote Monitoring Solution for Digital Factory

Remote Monitoring Solution for Digital Factory

Remote Monitoring Solution for Digital Factory Applications and Cases Key Takeaways Remote…

Learn More →
See All Cases

Frequently Asked Questions

What configurations and optional features are available on the IG902?

The IG902 is a high-performance edge gateway that supports Python applications and Docker containers on InHand’s custom embedded platform. Each unit ships with 1× RS-232 + 1× RS-485 serial as standard, in two base configurations:

  • B (Basic) — 512 MB RAM, optional Wi-Fi, no built-in I/O
  • H (High) — 1 GB RAM, dual-band Wi-Fi, 4× DI + 3× DO + relay output

Optional -D485 suffix replaces the RS-232 with a second RS-485 (2× RS-485 total). Part number template: IG902-- . Cellular module options: LQA8 (China), FS39 (NA Cat 6), FQ58 (EMEA/APAC), FQ78 (AU/LatAm), FQ88 (Japan), FQ98 (South Korea), or EN00 (no cellular).

Install the antennas, insert the SIM card, and connect the power adapter. Connect a computer via Ethernet — the IG902 has port-specific default IPs: GE0/1 = 192.168.1.1 ; GE0/2 = 192.168.2.1 . Set your adapter to DHCP or a 192.168.2.x static IP. Open a browser and go to https://192.168.2.1 (accept the self-signed certificate). Log in with username adm and the password on the device nameplate.

With the device powered off, insert the SIM card. Power on — the IG902 auto-detects the carrier and applies the matching APN in most cases, so no manual setup is needed. If the cellular link does not come up, log in, go to Network > Cellular, configure the APN per your carrier’s requirements, and click Apply. Verify by checking the MODEM LED and the 3 signal LEDs: MODEM steady on = dial successful (connected); MODEM flashing = dialing. Signal LEDs lit (1 / 1+2 / 1+2+3) indicate poor / moderate / good cellular signal.

The IG902 supports Docker containers and Python runtime for custom application deployment, plus InHand Device Supervisor for industrial protocol data collection and device monitoring.

You May Also Like