An All-in-One 4G Outdoor Router for Distributed Sites
All-in-One Antenna Design
Combines the router and antennas in a sealed enclosure, eliminating external antenna installation and simplifying deployment.
Reduced Signal Loss
Integrated antennas avoid long RF feeder cables, helping preserve cellular signal quality and connection stability.
Flexible PoE Deployment
IEEE 802.3af PoE carries power and data over one cable, with 9–36 V DC input for added flexibility.
Resilient Connectivity
Dual-SIM failover, cellular and wired backup, heartbeat monitoring, and a hardware watchdog help keep services online.
Secure Remote Networking
A stateful firewall and multiple VPN protocols protect business data and enable secure remote connectivity.
Cloud-Managed Outdoor Reliability
IP65 protection and a -20°C to +70°C operating range support outdoor deployment, while Device Manager enables centralized monitoring, configuration, upgrades, and alerts.
-
Hardware Overview
المعالج 580 ميجاهرتزذاكرة 128 MB DDR2 SDRAMتخزين 32 MB SPI NOR Flash4G Module 4G LTE Cat.4, 150 Mbps DL / 50 Mbps ULRecommended User Count 32منافذ إيثرنت 2 × 10/100 Mbps RJ45, WAN/LAN switchable, LAN2 supports PoE inputفتحات شريحة SIM 2 × Nano SIM (drawer-type socket), dual-card failoverالإدخال/الإخراج الرقمي 2 × configurable as DI or DOهوائي خلوي 2 × built-in 4G antennas (ANT_4G_1, ANT_4G_2)هوائي واي فاي 1 × built-in Wi-Fi antennaواي فاي IEEE 802.11 b/g/n, 2.4 GHz, up to 150 MbpsWi-Fi Transmit Power 802.11b: 16 dBm ± 2 dBm (11 Mbps) 802.11g: 16 dBm ± 2 dBm (54 Mbps) [email protected] GHz HT20 MCS7: 16 dBm ± 2 dBm [email protected] GHz HT40 MCS7: 16 dBm ± 2 dBmمؤشرات LED System, Wi-Fi, Cellular, Ethernetزر إعادة الضبط Pin-hole Reset buttonمدخل الطاقة DC 9–36 V (4-pin combined power and I/O terminal, over-current and reverse-polarity protected) IEEE 802.3af PoE inputStandby Power Consumption 90–110 mA @ 12 VOperating Power Consumption 280–300 mA @ 12 VPeak Power Consumption 340–360 mA @ 12 Vالحماية من دخول الأجسام الغريبة IP65حاوية البلاستيكدرجة حرارة التشغيل -20 درجة مئوية ~ +70 درجة مئويةدرجة حرارة التخزين -40 درجة مئوية ~ +85 درجة مئويةرطوبة 5% ~ 95% (non-condensing)أبعاد 164 × 50 × 129.7 mmوزن Approx. 500 gتثبيت Wall-mount, pole-mount, top-mount
-
Device Manager Cloud Management
Device Onboarding Device Manager cloud platform and custom server supportالإدارة عن بعد Device status query, remote configuration delivery, firmware upgrade, remote rebootBatch O&M Batch configuration and maintenance for large-scale device fleetsSNMP Management SNMP v1/v2c/v3, with Trap alarm reportingإدارة حركة المرور Traffic threshold, traffic statistics, and traffic alarmAlarm Types System reboot, LAN port up/down, traffic alarm, SIM card failureNotification Method Email alarm (configurable)
-
Mechanical Reliability
صدمة IEC 60068-2-27اهتزاز IEC 60068-2-6السقوط الحر IEC 60068-2-32
-
EMC Immunity
ESD (Electrostatic Discharge) EN 61000-4-2, Level 2Radiated RF Immunity EN 61000-4-3, Level 2EFT/Burst EN 61000-4-4, Level 2طفرة EN 61000-4-5, Level 2Conducted RF Immunity EN 61000-4-6, Level 2Oscillatory Wave Immunity EN 61000-4-12, Level 2Power-Frequency Magnetic Field Immunity EN 61000-4-8, 400 A/m
-
Certifications and Compliance
لجنة الاتصالات الفيدرالية CompletedIC Completedمجلس مراجعة البرامج التلفزيونية Completedشركة AT&T In‑progressفيريزون In‑progressتي موبايل In‑progressعلامة CE In‑progress
الباقة القياسية*
- ODU302 Outdoor Router ×1
- 1m Ethernet Cable ×1
- Wall‑mount Bracket ×1
- Pole‑mount Clamp ×1
- SIM Eject Pin ×1
- Outdoor Waterproof Connector ×2
- Outdoor Waterproof Cover ×2
- Outdoor Waterproof Nut ×1
- Expansion Bolts and Screws Set ×1
*تختلف محتويات العبوة القياسية باختلاف رموز الائتمان القياسية.
ملحقات اختيارية
- DC Power Adapter ×1
- PoE Injector ×1
- AC Power Cord ×1
اتصل بنا للحصول على مزيد من المعلومات حول خيارات التغليف لدينا، يرجى الاتصال بنا مباشرة.
تحديد
-
Hardware Overview
المعالج 580 ميجاهرتزذاكرة 128 MB DDR2 SDRAMتخزين 32 MB SPI NOR Flash4G Module 4G LTE Cat.4, 150 Mbps DL / 50 Mbps ULRecommended User Count 32منافذ إيثرنت 2 × 10/100 Mbps RJ45, WAN/LAN switchable, LAN2 supports PoE inputفتحات شريحة SIM 2 × Nano SIM (drawer-type socket), dual-card failoverالإدخال/الإخراج الرقمي 2 × configurable as DI or DOهوائي خلوي 2 × built-in 4G antennas (ANT_4G_1, ANT_4G_2)هوائي واي فاي 1 × built-in Wi-Fi antennaواي فاي IEEE 802.11 b/g/n, 2.4 GHz, up to 150 MbpsWi-Fi Transmit Power 802.11b: 16 dBm ± 2 dBm (11 Mbps) 802.11g: 16 dBm ± 2 dBm (54 Mbps) [email protected] GHz HT20 MCS7: 16 dBm ± 2 dBm [email protected] GHz HT40 MCS7: 16 dBm ± 2 dBmمؤشرات LED System, Wi-Fi, Cellular, Ethernetزر إعادة الضبط Pin-hole Reset buttonمدخل الطاقة DC 9–36 V (4-pin combined power and I/O terminal, over-current and reverse-polarity protected) IEEE 802.3af PoE inputStandby Power Consumption 90–110 mA @ 12 VOperating Power Consumption 280–300 mA @ 12 VPeak Power Consumption 340–360 mA @ 12 Vالحماية من دخول الأجسام الغريبة IP65حاوية البلاستيكدرجة حرارة التشغيل -20 درجة مئوية ~ +70 درجة مئويةدرجة حرارة التخزين -40 درجة مئوية ~ +85 درجة مئويةرطوبة 5% ~ 95% (non-condensing)أبعاد 164 × 50 × 129.7 mmوزن Approx. 500 gتثبيت Wall-mount, pole-mount, top-mount
-
Device Manager Cloud Management
Device Onboarding Device Manager cloud platform and custom server supportالإدارة عن بعد Device status query, remote configuration delivery, firmware upgrade, remote rebootBatch O&M Batch configuration and maintenance for large-scale device fleetsSNMP Management SNMP v1/v2c/v3, with Trap alarm reportingإدارة حركة المرور Traffic threshold, traffic statistics, and traffic alarmAlarm Types System reboot, LAN port up/down, traffic alarm, SIM card failureNotification Method Email alarm (configurable)
-
Mechanical Reliability
صدمة IEC 60068-2-27اهتزاز IEC 60068-2-6السقوط الحر IEC 60068-2-32
-
EMC Immunity
ESD (Electrostatic Discharge) EN 61000-4-2, Level 2Radiated RF Immunity EN 61000-4-3, Level 2EFT/Burst EN 61000-4-4, Level 2طفرة EN 61000-4-5, Level 2Conducted RF Immunity EN 61000-4-6, Level 2Oscillatory Wave Immunity EN 61000-4-12, Level 2Power-Frequency Magnetic Field Immunity EN 61000-4-8, 400 A/m
-
Certifications and Compliance
لجنة الاتصالات الفيدرالية CompletedIC Completedمجلس مراجعة البرامج التلفزيونية Completedشركة AT&T In‑progressفيريزون In‑progressتي موبايل In‑progressعلامة CE In‑progress
التنزيلات
الطلب
الباقة القياسية*
- ODU302 Outdoor Router ×1
- 1m Ethernet Cable ×1
- Wall‑mount Bracket ×1
- Pole‑mount Clamp ×1
- SIM Eject Pin ×1
- Outdoor Waterproof Connector ×2
- Outdoor Waterproof Cover ×2
- Outdoor Waterproof Nut ×1
- Expansion Bolts and Screws Set ×1
*تختلف محتويات العبوة القياسية باختلاف رموز الائتمان القياسية.
ملحقات اختيارية
- DC Power Adapter ×1
- PoE Injector ×1
- AC Power Cord ×1
اتصل بنا للحصول على مزيد من المعلومات حول خيارات التغليف لدينا، يرجى الاتصال بنا مباشرة.
مدير الجهاز
سحابة إدارة الأجهزة
إدارة مركزية لأجهزة التوجيه والبوابات الصناعية من InHand مع مراقبة مرئية، بالإضافة إلى سهولة التكوين والترقية عن بعد.
مدير الجهاز
قضايا ذات صلة
Scanning & CCTV Connectivity in Steel-Frame Warehouses
Keep scanning fast and footage intact in steel-frame warehouses. Mounted on the...
تعرّف على المزيد →
Construction-Site Security Surveillance — Site-Office & Pole Camera Networking
Give every site "an office with Wi-Fi and surveillance that never drops."...
تعرّف على المزيد →
Underground-Parking EV Charging — Entrance Deployment Bridges the Charger Data Link
InHand ODU302 outdoor 4G router delivers reliable EV charging connectivity with LTE...
تعرّف على المزيد →الأسئلة الشائعة
What is the ODU302, and how is it different from a standard indoor router?
The ODU302 is an industrial-grade outdoor 4G wireless router that integrates a high-performance router with high-gain cellular and Wi-Fi antennas in a single IP65-rated enclosure.
It can be mounted directly on top of ATMs, EV chargers, self-service terminals, or control cabinets, helping reduce the space, installation effort, and signal loss associated with cabinet-mounted routers, external antennas, and long RF feeder cables.
What are the typical applications for the ODU302?
Typical applications include:
- Financial self-service equipment, such as ATMs
- Smart energy equipment, such as outdoor EV chargers
- Self-service retail equipment, such as vending machines
- Outdoor industrial control cabinets
These applications typically require outdoor protection, compact installation, reduced feeder loss, fast deployment, dual-link or dual-SIM redundancy, and centralized remote management at scale.
What are the benefits of the all-in-one antenna and router design and “zero feeder loss”?
The ODU302 integrates the RF module and optimized built-in antennas into the same outdoor unit, eliminating the need for long coaxial feeder cables between an indoor router and external antennas.
This helps reduce feeder attenuation in high-frequency LTE applications, while also simplifying antenna selection, wall penetration, cabling, cabinet space requirements, and on-site installation.
“Zero feeder loss” refers specifically to the benefit of eliminating external long feeder cables. It does not mean that the wireless link is free from propagation loss or environmental interference. Actual performance still depends on factors such as carrier coverage, frequency bands, installation location, and surrounding obstructions.
Can the ODU302 use a single Ethernet cable for both power and data?
Yes. The ODU302 is an IEEE 802.3af-compliant PoE powered device (PD). Its LAN2 port supports both power and data transmission over a single Ethernet cable.
The device also supports 9–36 V DC input via an industrial terminal block, allowing users to choose the most suitable power option based on site conditions.
For PoE deployments, the power sourcing equipment, cable length, wire gauge, and voltage drop should still be checked against IEEE 802.3af requirements and actual installation conditions.