اسأل الذكاء الاصطناعي أي شيء

وكيل DeviceSupervisor™

Collect, process, convert, and send industrial data to the cloud—all with low-code or no-code setup.

وكيل DeviceSupervisor™

Collect, process, convert, and send industrial data to the cloud—all with low-code or no-code setup.

برنامج وكيل الحافة الصناعية

Connect Industrial Devices

80+ protocols for PLCs, meters, CNC machines, robots, building systems, and utility equipment.

Bridge Systems and Cloud

Convert data to OPC UA, IEC 104, BACnet, DNP3.0, or SNMP. Connect to the cloud via MQTT or Sparkplug B.

Process Data at the Edge

Map, calculate, group, alert, and store data. Use Python scripts in QuickFunction for custom logic.

اتصال إيثرنت

Simplify Setup and Maintenance

Import/export Excel and CSV files, reuse device templates, and inspect live communication messages.

Connect Industrial Devices

80+ protocols for PLCs, meters, CNC machines, robots, building systems, and utility equipment.

Bridge Systems and Cloud

Convert data to OPC UA, IEC 104, BACnet, DNP3.0, or SNMP. Connect to the cloud via MQTT or Sparkplug B.

 

معالجة البيانات المحلية

Process Data at the Edge

Map, calculate, group, alert, and store data. Use Python scripts in QuickFunction for custom logic.

Simplify Setup and Maintenance

Import/export Excel and CSV files, reuse device templates, and inspect live communication messages.

  • Target Markets
    Smart Power Substation SCADA/telecontrol, meter reading, DTU/FTU, PV / storage monitoring
    Smart Energy BMS battery management, microgrid coordination, EMS energy management
    التصنيع الذكي PLC data acquisition, CNC connectivity, equipment OEE analytics, industrial cloud enablement
    Building Automation BACnet/Modbus acquisition, HVAC control, power monitoring
    Smart Environmental HJ212 emissions monitoring, pollution source tracking, water utility telemetry
    Smart Water Utilities Water meter acquisition, SL651 water resource telemetry, remote pump-station O&M
    Smart Transportation Tunnel monitoring, roadside equipment connectivity, EV charging station management
    Oil & Gas Modbus/OPC UA tank farm monitoring, oilfield data acquisition
  • Module Descriptions
    ① Southbound Acquisition 80+ protocol drivers; supports Ethernet / RS485 / RS232; concurrent multi-device polling
    ② DataHub Internal MQTT event bus for data mapping, operations, grouping, historical storage, and alarming
    ③ QuickFunction Python scripting engine with periodic, message, and boot trigger modes
    ④ Northbound Protocol Conversion 10+ northbound server protocols with concurrent multi-protocol output
    ⑤ Northbound Cloud Services Concurrent multi-cloud publishing including MQTT, Sparkplug B, AliCloud, AWS, Azure, etc.
  • PLC Protocols (40+)
    Rockwell / Allen-Bradley EtherNet/IP (CompactLogix / Micro / MicroLogix / Unconnected), SLC Net
    Siemens ISO on TCP (S200 / S200 Smart / S1200 / S1500), PPI, PPI over TCP, Fetch/Write
    Mitsubishi FX Links (Serial/TCP), FX Serial over TCP, MC 1E/3E/3C, MC 3C over TCP, MC R, MITSUBISHI Programming Port
    Omron C-Mode (Serial/TCP), EtherNet/IP CompactLogix, FINS TCP/UDP, HostLink (Serial/TCP)
    Beckhoff ADS
    Delta Delta TCP, Delta Serial, Delta Serial ASCII, Delta Serial over TCP
    FATEK FATEK Programming Port (Serial/TCP)
    Fuji SPB (Serial/TCP), SPH Net
    General Electric SRTP
    Inovance INOVANCE Serial, INOVANCE TCP, INOVANCE Serial over TCP
    KEBA KEBA Socket
    Keyence KEYENCE MC 3E
    Panasonic Mewtocol (Serial/TCP), Panasonic MC 3E, Nano (Serial/TCP)
    VIGOR VIGOR Serial, VIGOR Serial over TCP
    XINJE XINJE TCP (Dedicated), XINJE TCP (Modbus), XINJE Serial, XINJE Serial over TCP
    Yokogawa Link TCP
    Generic Modbus RTU / ASCII / TCP / RTU over TCP / RTU Slave, OPC DA, OPC UA, OPC UA PubSub, Euromap-63 (Injection Molding), WebApi
  • Northbound Protocol Conversion List (10+)
    Modbus TCP Slave بروتوكول التحكم بالنقل (TCP)
    Modbus RTU Slave RS232/485
    OPC UA Server بروتوكول التحكم بالنقل (TCP)
    IEC 104 Server بروتوكول التحكم بالنقل (TCP)
    IEC 101 Server RS232/485, TCP
    IEC 61850 Server بروتوكول التحكم بالنقل (TCP)
    BACnet IP Server بروتوكول UDP
    BACnet MS/TP Server RS232/485
    DNP3 Outstation TCP/UDP
    SNMP Agent بروتوكول UDP
    SL651-2014 بروتوكول التحكم بالنقل (TCP)
    HJ212 Client بروتوكول التحكم بالنقل (TCP)
  • Northbound Cloud Service List
    Standard MQTT Generic
    MQTT Sparkplug B معيار
    InHand iSCADA Cloud متوفر
    InHand XEnergy متوفر
    InHand XEnergy (IEC104) متوفر
    AliCloud IoT Alibaba
    AWS IoT Amazon
    Azure IoT Microsoft
    Siemens MindSphere (Insights Hub) Siemens
  • Three Trigger Modes
    Periodic Trigger Executes at fixed intervals (seconds / minutes / hours); ideal for scheduled data processing, aggregation, and reporting
    Local Subscription Message Trigger Subscribes to the internal MQTT event bus; triggers on message arrival — ideal for event-driven workflows
    Boot Trigger Executes once at DSA startup; ideal for initialization tasks
  • QuickFunction API Reference
    Data Publish Publish measurement points / alarms / custom data to cloud (publish QuickFunction)
    Data Write Update controller measurement point values (write)
    Data Recall Retrieve controller measurement point data (recall)
    Global Parameters Read global parameters, controller connection status, cloud connection status, global configuration
    File I/O Read / write files from within scripts
    Time-Series DB LwTSDB general API: insert / find / delete
    Sparkplug B Publish NBIRTH / NDATA; subscribe to NCMD
  • Internal MQTT Event Bus
    MQTT Broker Address 127.0.0.1
    Port (Docker network)
    Southbound Read Topic `ds2/eventbus/south/read/{driverServiceId}`
  • Tag Configuration
    Controller Management Add / edit / copy / delete / disable / enable controllers
    Tag Management Add / import / export / delete tags; Excel bulk configuration
    Device Templates Save common device configurations as templates; one-click deployment of identical devices
    Data Mapping & Operations Data type conversion, byte-order adjustment, arithmetic operations, value mapping
    Data Grouping Group tags by business / scenario for easier reporting and querying
    Real-Time Communication Messages Online view / download of southbound controller messages for O&M troubleshooting
  • Data Type Support
    16 Bit Int AB, BA (default AB)
    32 Bit Int ABCD, CDAB, DCBA, BADC (default ABCD)
    32 Bit Float ABCD, CDAB, DCBA, BADC (default ABCD)
    64 Bit Int ABCDEFGH, GHEFCDAB, HGEFDCBA, BADCFEHG (default ABCDEFGH)
    64 Bit Float ABCDEFGH, GHEFCDAB, HGEFDCBA, BADCFEHG (default ABCDEFGH)
  • Alarm Engine
    Alarm Levels 5 levels: Notice / Warning / Minor / Major / Critical
    Comparison Operators `=`, `!=`, `>`, `≥`, `<`, `≤`
    Logical Operators No logic / && (AND) / || (OR)
    Alarm Labels Group alarm items; MQTT reporting can select by label
    Historical Alarms Historical alarm records including trigger / restoration time and values
    CSV Import / Export Bulk alarm rule management
  • Storage Configuration
    Log Level DEBUG / INFO / WARNING / ERROR (default INFO)
    Max Historical Alarms Per-alarm maximum (default 2000)
    Offline Data Storage USB / SD Card / Gateway Storage (default Gateway Storage)
    Offline Data Max Maximum records (default 10000)
    Offline Data Upload Period ms (default 200)
    Offline Data Report Timeout ms (default 1000)
    Offline Data Report Strategy Offline-priority / Realtime-priority (default Offline-priority)
    Offline Data Retransmit Strategy Continuous retry / Discard after limit (default Continuous retry)
    Max Retry Count Applied when "Discard after limit" (default 3)
    Communication Message Storage USB / SD Card / Gateway Storage (default Gateway Storage)
    Max Communication Messages (default 2000)
  • IG502 (Entry-Level Industrial Gateway)
    Modbus TCP 10s
    Modbus RTU 10s
    OPC UA 10s
  • IG902 (Mainstream Industrial Gateway)
    Modbus TCP 10s
    Modbus RTU 10s
    OPC UA 10s
  • IG532 (High-End Industrial Gateway)
    Modbus TCP 10s
    Modbus RTU 10s
    OPC UA 10s
  • EC312 (Entry-Level Edge Computer)
    Modbus TCP 10s
    Modbus RTU 10s
    OPC UA 10s
  • EC942 (Flagship Edge Computer)
    Modbus TCP 10s
    Modbus RTU 10s
    OPC UA 10s
  • System Requirements
    نظام التشغيل InHand custom Linux (kernel 5.x based)
    CPU Architecture ARM Cortex-A7 / A53 / A55 / A72
    Minimum RAM 256MB (IG series) / 512MB (EC series)
    Minimum Storage 512MB Flash
    شبكة Ethernet / 4G / 5G / Wi-Fi (per hardware)
    Web Configuration Browser Chrome 90+ / Edge 90+ / Firefox 88+
  • Licensing Models
    Hardware Embedded IG series ships with full DSA functionality; no separate license required
    EC Series APP EC series can install DSA as an APP with corresponding license
    Enterprise Subscription Enterprise annual subscription available for large-scale deployments, including technical support and cloud management
  • Services & Support
    Technical Documentation User manuals, API references, protocol integration guides
    Online Knowledge Base help.inhand.com — 24/7 access
    الدعم الفني Email / phone / remote support
    Software Upgrades Free major version upgrades (within license validity)
    Protocol Extension Custom new protocols available upon customer request

Datasheets

DeviceSupervisor Agent_Datasheet_V1.0
10.30.2026 1.1 MB
تحديد
  • Target Markets
    Smart Power Substation SCADA/telecontrol, meter reading, DTU/FTU, PV / storage monitoring
    Smart Energy BMS battery management, microgrid coordination, EMS energy management
    التصنيع الذكي PLC data acquisition, CNC connectivity, equipment OEE analytics, industrial cloud enablement
    Building Automation BACnet/Modbus acquisition, HVAC control, power monitoring
    Smart Environmental HJ212 emissions monitoring, pollution source tracking, water utility telemetry
    Smart Water Utilities Water meter acquisition, SL651 water resource telemetry, remote pump-station O&M
    Smart Transportation Tunnel monitoring, roadside equipment connectivity, EV charging station management
    Oil & Gas Modbus/OPC UA tank farm monitoring, oilfield data acquisition
  • Module Descriptions
    ① Southbound Acquisition 80+ protocol drivers; supports Ethernet / RS485 / RS232; concurrent multi-device polling
    ② DataHub Internal MQTT event bus for data mapping, operations, grouping, historical storage, and alarming
    ③ QuickFunction Python scripting engine with periodic, message, and boot trigger modes
    ④ Northbound Protocol Conversion 10+ northbound server protocols with concurrent multi-protocol output
    ⑤ Northbound Cloud Services Concurrent multi-cloud publishing including MQTT, Sparkplug B, AliCloud, AWS, Azure, etc.
  • PLC Protocols (40+)
    Rockwell / Allen-Bradley EtherNet/IP (CompactLogix / Micro / MicroLogix / Unconnected), SLC Net
    Siemens ISO on TCP (S200 / S200 Smart / S1200 / S1500), PPI, PPI over TCP, Fetch/Write
    Mitsubishi FX Links (Serial/TCP), FX Serial over TCP, MC 1E/3E/3C, MC 3C over TCP, MC R, MITSUBISHI Programming Port
    Omron C-Mode (Serial/TCP), EtherNet/IP CompactLogix, FINS TCP/UDP, HostLink (Serial/TCP)
    Beckhoff ADS
    Delta Delta TCP, Delta Serial, Delta Serial ASCII, Delta Serial over TCP
    FATEK FATEK Programming Port (Serial/TCP)
    Fuji SPB (Serial/TCP), SPH Net
    General Electric SRTP
    Inovance INOVANCE Serial, INOVANCE TCP, INOVANCE Serial over TCP
    KEBA KEBA Socket
    Keyence KEYENCE MC 3E
    Panasonic Mewtocol (Serial/TCP), Panasonic MC 3E, Nano (Serial/TCP)
    VIGOR VIGOR Serial, VIGOR Serial over TCP
    XINJE XINJE TCP (Dedicated), XINJE TCP (Modbus), XINJE Serial, XINJE Serial over TCP
    Yokogawa Link TCP
    Generic Modbus RTU / ASCII / TCP / RTU over TCP / RTU Slave, OPC DA, OPC UA, OPC UA PubSub, Euromap-63 (Injection Molding), WebApi
  • Northbound Protocol Conversion List (10+)
    Modbus TCP Slave بروتوكول التحكم بالنقل (TCP)
    Modbus RTU Slave RS232/485
    OPC UA Server بروتوكول التحكم بالنقل (TCP)
    IEC 104 Server بروتوكول التحكم بالنقل (TCP)
    IEC 101 Server RS232/485, TCP
    IEC 61850 Server بروتوكول التحكم بالنقل (TCP)
    BACnet IP Server بروتوكول UDP
    BACnet MS/TP Server RS232/485
    DNP3 Outstation TCP/UDP
    SNMP Agent بروتوكول UDP
    SL651-2014 بروتوكول التحكم بالنقل (TCP)
    HJ212 Client بروتوكول التحكم بالنقل (TCP)
  • Northbound Cloud Service List
    Standard MQTT Generic
    MQTT Sparkplug B معيار
    InHand iSCADA Cloud متوفر
    InHand XEnergy متوفر
    InHand XEnergy (IEC104) متوفر
    AliCloud IoT Alibaba
    AWS IoT Amazon
    Azure IoT Microsoft
    Siemens MindSphere (Insights Hub) Siemens
  • Three Trigger Modes
    Periodic Trigger Executes at fixed intervals (seconds / minutes / hours); ideal for scheduled data processing, aggregation, and reporting
    Local Subscription Message Trigger Subscribes to the internal MQTT event bus; triggers on message arrival — ideal for event-driven workflows
    Boot Trigger Executes once at DSA startup; ideal for initialization tasks
  • QuickFunction API Reference
    Data Publish Publish measurement points / alarms / custom data to cloud (publish QuickFunction)
    Data Write Update controller measurement point values (write)
    Data Recall Retrieve controller measurement point data (recall)
    Global Parameters Read global parameters, controller connection status, cloud connection status, global configuration
    File I/O Read / write files from within scripts
    Time-Series DB LwTSDB general API: insert / find / delete
    Sparkplug B Publish NBIRTH / NDATA; subscribe to NCMD
  • Internal MQTT Event Bus
    MQTT Broker Address 127.0.0.1
    Port (Docker network)
    Southbound Read Topic `ds2/eventbus/south/read/{driverServiceId}`
  • Tag Configuration
    Controller Management Add / edit / copy / delete / disable / enable controllers
    Tag Management Add / import / export / delete tags; Excel bulk configuration
    Device Templates Save common device configurations as templates; one-click deployment of identical devices
    Data Mapping & Operations Data type conversion, byte-order adjustment, arithmetic operations, value mapping
    Data Grouping Group tags by business / scenario for easier reporting and querying
    Real-Time Communication Messages Online view / download of southbound controller messages for O&M troubleshooting
  • Data Type Support
    16 Bit Int AB, BA (default AB)
    32 Bit Int ABCD, CDAB, DCBA, BADC (default ABCD)
    32 Bit Float ABCD, CDAB, DCBA, BADC (default ABCD)
    64 Bit Int ABCDEFGH, GHEFCDAB, HGEFDCBA, BADCFEHG (default ABCDEFGH)
    64 Bit Float ABCDEFGH, GHEFCDAB, HGEFDCBA, BADCFEHG (default ABCDEFGH)
  • Alarm Engine
    Alarm Levels 5 levels: Notice / Warning / Minor / Major / Critical
    Comparison Operators `=`, `!=`, `>`, `≥`, `<`, `≤`
    Logical Operators No logic / && (AND) / || (OR)
    Alarm Labels Group alarm items; MQTT reporting can select by label
    Historical Alarms Historical alarm records including trigger / restoration time and values
    CSV Import / Export Bulk alarm rule management
  • Storage Configuration
    Log Level DEBUG / INFO / WARNING / ERROR (default INFO)
    Max Historical Alarms Per-alarm maximum (default 2000)
    Offline Data Storage USB / SD Card / Gateway Storage (default Gateway Storage)
    Offline Data Max Maximum records (default 10000)
    Offline Data Upload Period ms (default 200)
    Offline Data Report Timeout ms (default 1000)
    Offline Data Report Strategy Offline-priority / Realtime-priority (default Offline-priority)
    Offline Data Retransmit Strategy Continuous retry / Discard after limit (default Continuous retry)
    Max Retry Count Applied when "Discard after limit" (default 3)
    Communication Message Storage USB / SD Card / Gateway Storage (default Gateway Storage)
    Max Communication Messages (default 2000)
  • IG502 (Entry-Level Industrial Gateway)
    Modbus TCP 10s
    Modbus RTU 10s
    OPC UA 10s
  • IG902 (Mainstream Industrial Gateway)
    Modbus TCP 10s
    Modbus RTU 10s
    OPC UA 10s
  • IG532 (High-End Industrial Gateway)
    Modbus TCP 10s
    Modbus RTU 10s
    OPC UA 10s
  • EC312 (Entry-Level Edge Computer)
    Modbus TCP 10s
    Modbus RTU 10s
    OPC UA 10s
  • EC942 (Flagship Edge Computer)
    Modbus TCP 10s
    Modbus RTU 10s
    OPC UA 10s
  • System Requirements
    نظام التشغيل InHand custom Linux (kernel 5.x based)
    CPU Architecture ARM Cortex-A7 / A53 / A55 / A72
    Minimum RAM 256MB (IG series) / 512MB (EC series)
    Minimum Storage 512MB Flash
    شبكة Ethernet / 4G / 5G / Wi-Fi (per hardware)
    Web Configuration Browser Chrome 90+ / Edge 90+ / Firefox 88+
  • Licensing Models
    Hardware Embedded IG series ships with full DSA functionality; no separate license required
    EC Series APP EC series can install DSA as an APP with corresponding license
    Enterprise Subscription Enterprise annual subscription available for large-scale deployments, including technical support and cloud management
  • Services & Support
    Technical Documentation User manuals, API references, protocol integration guides
    Online Knowledge Base help.inhand.com — 24/7 access
    الدعم الفني Email / phone / remote support
    Software Upgrades Free major version upgrades (within license validity)
    Protocol Extension Custom new protocols available upon customer request

Datasheets

DeviceSupervisor Agent_Datasheet_V1.0
10.30.2026 1.1 MB

المنتجات ذات الصلة

قضايا ذات صلة

معاينة
توزيع ذكي للطاقة ذات الجهد المنخفض

توزيع ذكي للطاقة ذات الجهد المنخفض

تطبيقات وحالات توزيع الطاقة الذكية ذات الجهد المنخفض - أهم النقاط الرئيسية: أنظمة الجهد المنخفض الذكية...

تعرّف على المزيد →
اطلع على جميع الحالات

الأسئلة الشائعة

Where can DSA be used?

Power, energy, manufacturing, buildings, environmental monitoring, water, transport, and petrochemicals—including PLC data collection and energy management.

80+ protocols for PLCs, RTUs, meters, building controllers, robots, and utility instruments. Custom access via Easy COM and Easy TCP.

Standard MQTT and MQTT Sparkplug B, with support for AWS IoT, Azure IoT, and Alibaba Cloud IoT.

Runs on IG502/IG902 gateways and EC312/EC942/EC954/EC3320 edge computers. Requires Linux on ARM, at least 512 MB RAM (IG) or 1 GB (EC), and 8 GB storage.

قد يعجبك أيضاً